• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 BARDEX LUBRI-SIL ALL-SILICONE FOLEY CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 BARDEX LUBRI-SIL ALL-SILICONE FOLEY CATHETER Back to Search Results
Catalog Number 175812
Device Problems Partial Blockage (1065); Complete Blockage (1094)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Date 06/29/2020
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that the catheters had blocked within a couple of days of being inserted.
 
Event Description
It was reported that the catheters had blocked within a couple of days of being inserted.
 
Manufacturer Narrative
The reported event was inconclusive.No sample was returned for evaluation.A potential root cause for this failure could be, "blocked by clots".The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: "visually inspect the product for any imperfections or surface deterioration prior to use.If package is opened or if any imperfection or surface deterioration is observed, do not use.1.Open outer white wrapping to prepare sterile field and place underpad beneath patient, plastic side down.2.If patient has a catheter in-situ to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, reseat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.Wait at least 30 seconds for deflation.If permitted by local protocol, the valve arm may be severed.If this fails, contact adequately trained professional for assistance as directed by local protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.3.Put on gloves, cover patient with fenestrated drape with open exposing location where catheter will be inserted, and place the apron on yourself.4.Using the two (2) syringes, marked ¿for cleansing purposes only¿, dispense the water onto three (3) gauze squares.Prepare the patient by wiping down the catheter insertion site with the saturated gauze squares.Dry patient with the remaining two (2) gauze squares.Note: do not use this syringe to inflate the catheter balloon.5.Prepare the lubricating gel syringe by removing the cap from the syringe tip.6.For easing with the insertion of the catheter into the patient dispense the lubricating gel into the urethra (according to local protocol).7 remove top tray and open plastic pouch (sleeve) surrounding the catheter.8.Proceed with catheterisation according to local protocol.To inflate catheter, simply insert tip of sterile water-filled syringe gently into valve (do not overpenetrate) and depress plunger.Instill entire amount of sterile water - 10 ml.9.Attach statlock® foley stabilisation device to the bifurcation (y-shape) of the foley catheter (statlock® foley stabilisation device can be used for up to 7 days) and apply.(refer to the instructions for use provided with the statlock® foley stabilisation device pouch for more details).10.If the procedure pack includes a leg bag, utilise the leg straps provided to secure the leg bag to the patient¿s leg, making sure not to affect circulation or drainage of urine.11.Ensure catheter and drainage bag tubing is kink free and drainage bag is positioned below the bladder to ensure urine is flowing freely.Periodic inspection of this system should be made to ensure that urine is flowing freely.If a standing column of urine is observed, check for correct positioning of bag and then for a physical obstruction.If correct positioning or removal of physical obstruction does not allow free flow, further investigation should be taken in line with local protocol.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDEX LUBRI-SIL ALL-SILICONE FOLEY CATHETER
Type of Device
FOLEY CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key10307596
MDR Text Key200802045
Report Number1018233-2020-04669
Device Sequence Number1
Product Code EZL
Combination Product (y/n)N
PMA/PMN Number
K984084
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,other
Type of Report Initial,Followup
Report Date 09/18/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/22/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date12/31/2022
Device Catalogue Number175812
Device Lot NumberNGDZ3290
Was Device Available for Evaluation? No
Date Manufacturer Received08/28/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-