Model Number SET ROTAREX®S 6F X 135CM
Device Problems Use of Device Problem (1670); Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Perforation (2001); Perforation of Vessels (2135)
Event Date 07/13/2020
Event Type  Injury  
Manufacturer Narrative
Device was discarded at the hopsital.Investigation will be performed without the device.
 
Event Description
Dr.(b)(6) cardiologist was the operator.It was an occlusion of the sfa.Vessel size was 4mm.Device was used in a 65cm 6f pinnacle sheath and over the.018 rotarex wire included with the device.The device perforated the vessel at the mid-sfa segment.The vessel was treated with a balloon, dcb and stent following the perforation.The perforation was resolved after adjunctive therapy.
 
Manufacturer Narrative
Summary evaluation report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTAREXS 6F 135CM (STRAUB MEDICAL)
Type of Device
ATHERECTOMY CATHETER
Manufacturer (Section D)
STRAUB MEDICAL AG
straubstrasse 12
wangs, sankt gallen 7323
SZ  7323
MDR Report Key10384969
MDR Text Key202226733
Report Number3008439199-2020-00035
Device Sequence Number1
Product Code MCW
UDI-Device Identifier07640142810582
UDI-Public7640142810582
Combination Product (y/n)N
PMA/PMN Number
K172315
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 07/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date04/07/2023
Device Model NumberSET ROTAREX®S 6F X 135CM
Device Catalogue Number80237
Device Lot Number200600
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 07/15/2020
Initial Date FDA Received08/10/2020
Supplement Dates Manufacturer Received07/15/2020
Supplement Dates FDA Received10/15/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
-
-