Model Number 3820
Device Problems Inflation Problem (1310); Material Integrity Problem (2978)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/03/2020
Event Type  malfunction  
Manufacturer Narrative
(b)(6).Device evaluated by mfr: the device was returned for evaluation.A visual examination identified that the balloon wings had been subjected to positive pressure.The device was attached to an encore inflation unit and positive pressure was applied.Liquid was observed to be leaking from a balloon pinhole located approximately 3mm proximally of the distal marker band.An examination of the balloon material and marker bands identified no issues which could potentially have contributed to this complaint.The rated burst pressure for this device is 12 atmospheres.The blades of the device were visually and microscopically examined, and no issues were noted that may have potentially contributed to the complaint incident.All blades were present and fully bonded to the balloon surface.No issues were noted with the hypotube/shaft of the device.No issues were noted with the tip section of the device.A visual and microscopic examination found no issue with the marker bands.
 
Event Description
Reportable based on device analysis completed on 30sep2020.It was reported that the balloon could not inflate and was damaged.The 80% stenosed target lesion was located in the right coronary artery.A 06/3.50 flextome cutting balloon was selected for use.During procedure, it was noted that the balloon could not inflate and was found damaged.The procedure was completed with a different device.No patient complications were reported and patient was stable post procedure.However, device analysis revealed that there was balloon pinhole.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXTOME CUTTING BALLOON
Type of Device
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key10673125
MDR Text Key211459113
Report Number2134265-2020-14056
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeCH
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 10/13/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/13/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/21/2021
Device Model Number3820
Device Catalogue Number3820
Device Lot Number0022287685
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/08/2020
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/30/2020
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/22/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age61 YR
Patient Weight60
-
-