Model Number 71440311
Device Problem Connection Problem (2900)
Patient Problems No Known Impact Or Consequence To Patient (2692); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/21/2020
Event Type  malfunction  
Event Description
It was reported that there were metal shaving coming out of the impactor during the surgery, specifically from the grooves that lock the screws up and down.No delay reported.No patient injuries reported.An s&n backup was available.
 
Manufacturer Narrative
The associated device, used in treatment, were returned and evaluated.A visual inspection of the returned device confirmed the stated failure mode.The device clamp is loose, and device pin has fell out of device, rendering device inoperable.The device was manufactured in 2016 and shows signs of extensive use.A complaint history review found related failures; this failure mode will be monitored for future complaints and assessed for any necessary corrective actions.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.At this time, we do not have reason to suspect that the product failed to meet any product specifications at the time of manufacture.This device is a reusable instrument that can be exposed to numerous surgeries.Damage from prolonged use, misuse or rough handling are likely probable causes of the reported event.We recommend that all reusable instruments be routinely inspected for wear and damage and replaced as necessary.Based on this investigation, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GII MOD PAT REAMER GDE
Type of Device
PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
MDR Report Key10681335
MDR Text Key211435368
Report Number1020279-2020-05389
Device Sequence Number1
Product Code HRY
UDI-Device Identifier03596010462749
UDI-Public03596010462749
Combination Product (y/n)N
PMA/PMN Number
K121393
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 12/04/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number71440311
Device Catalogue Number71440311
Device Lot Number16BBG0042
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/08/2020
Initial Date Manufacturer Received 09/21/2020
Initial Date FDA Received10/14/2020
Supplement Dates Manufacturer Received12/01/2020
Supplement Dates FDA Received12/05/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-