• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY FRANCE SAS - 3003895575 UNKNOWN SHOULDER LOCKING SCREW

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY FRANCE SAS - 3003895575 UNKNOWN SHOULDER LOCKING SCREW Back to Search Results
Catalog Number UNK SHOULDER LOCKING SCREW
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Injury (2348); No Code Available (3191)
Event Date 01/29/2019
Event Type  Injury  
Manufacturer Narrative
(b)(4).Investigation summary: no device associated with this report was received for examination.A worldwide lot specific complaint database search, or device history record (dhr) review, was not possible because the required lot number was not provided.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.
 
Event Description
The literature article entitled, "delta xtend reverse shoulder arthroplasty ¿ results at a minimum of five years" written by craig m.Ball published by shoulder and elbow accepted by publisher 29 january 2019 was reviewed.The article's purpose was to review the clinical and radiographic outcomes of the delta xtend reverse shoulder arthroplasty at a minimum of five years.Data was compiled from 57 patients (59 shoulders) all implanted with delta xtend either uncemented modular stems or cemented monobloc between june 2007 and june 2012.Cement manufacturer is not identified.Figure 3 provides a radiographic image of a longer stem that replaced a primary delta xtend that was loose and associated with a fracture sequelae and proximal humeral bone loss.Adverse events: fracture sequelae with loose stem and proximal humeral bone loss (treated by revision to a longer stem.Intraoperative calcar fracture (no treatment specified).Axillary nerve palsy (listed a complication without recovery).Minor transient neuropraxia of the thumb and index finger (resolved completely within 3-6 months and had no effect on clinical outcome).Periprosthetic fracture of the metaglene post a fall (treated by revision).Symptomatic notching with pain (treated by revision of glenosphere and liner exchange).Stem subsidence (treatment not specified).Cortical resorption (treatment not specified).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN SHOULDER LOCKING SCREW
Type of Device
SHOULDER LOCKING SCREW
Manufacturer (Section D)
DEPUY FRANCE SAS - 3003895575
7 allee irene joliot-curie
b.p. 256
saint priest cedex 69801
FR  69801
Manufacturer (Section G)
LEEDS MFG & MATERIAL WAREHOUSE
st anthonys road
leeds LS11 8DT
UK   LS11 8DT
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr
b.p. 256
warsaw, IN 46581
6107428552
MDR Report Key10689807
MDR Text Key211657446
Report Number1818910-2020-22557
Device Sequence Number1
Product Code PHX
Combination Product (y/n)N
Reporter Country CodeNZ
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 10/01/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/16/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK SHOULDER LOCKING SCREW
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/01/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-