Model Number 595000-001
Device Problems Output Problem (3005); No Apparent Adverse Event (3189); Audible Prompt/Feedback Problem (4020)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/09/2020
Event Type  malfunction  
Manufacturer Narrative
The freedom driver will be returned to syncardia for evaluation.The results will be provided in a follow-up mdr.(b)(4) initial.
 
Event Description
The customer, a syncardia certified hospital, reported that the freedom driver exhibited intermittent fault alarms.There was no reported adverse patient impact.The customer also reported that the patient was subsequently switched to a backup driver.
 
Manufacturer Narrative
The driver's alarm history was reviewed and did not reveal any recorded alarms.Only permanent alarms are recorded in the drivers alarm history as intermittent and / or recoverable alarms are not recorded in the driver alarm history.The driver passed all sections of functional testing.During a 48-hour observation run, the driver did not maintain the proper normotensive pressure values for left arterial pressure (lap).The root cause of the customer-reported intermittent fault alarms could not be conclusively determined.(h6: 3189, 4756, 213, 67).The root cause the freedom driver did not maintain the proper normotensive lap values during testing was determined to be a malfunction of the piston cylinder assembly.This malfunction is unrelated to the customer-reported issue.(h6: 3005, 4756, 180, 4307).Syncardia has a corrective and preventive action (capa) for the issue of freedom driver out of specification left arterial pressure (lap).Syncardia has completed its investigation and is closing this file.(b)(4) follow-up report 1.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCARDIA FREEDOM DRIVER
Type of Device
EXTERNAL PNEUMATIC DRIVER
Manufacturer (Section D)
SYNCARDIA SYSTEMS, LLC
1992 e. silverlake road
tucson AZ 85713
Manufacturer (Section G)
SYNCARDIA SYSTEMS, LLC
1992 e. silverlake road
tucson AZ 85713
Manufacturer Contact
sagar pimpalwar
1992 e. silverlake road
tucson, AZ 85713
5205451234
MDR Report Key10705482
MDR Text Key214799576
Report Number3003761017-2020-00217
Device Sequence Number1
Product Code LOZ
UDI-Device Identifier00858000003121
UDI-Public(01)00858000003121
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,User Facility
Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date 08/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model Number595000-001
Device Catalogue Number595000-001
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/12/2020
Initial Date FDA Received10/20/2020
Supplement Dates Manufacturer Received10/12/2020
Supplement Dates FDA Received09/07/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/20/2018
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Age46 YR
Patient SexMale
-
-