MAUDE Adverse Event Report: ABBOTT VASCULAR XIENCE SIERRA EVEROLIMUS ELUTING CORONARY STENT SYSTEM; DRUG ELUTING CORONARY STENT DELIVERY SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ABBOTT VASCULAR XIENCE SIERRA EVEROLIMUS ELUTING CORONARY STENT SYSTEM; DRUG ELUTING CORONARY STENT DELIVERY SYSTEM Back to Search Results
Model Number 1550300-23
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Angina (1710); Non specific EKG/ECG Changes (1817); High Blood Pressure/ Hypertension (1908); Pericardial Effusion (3271)
Event Date 10/14/2020
Event Type  Injury  
Manufacturer Narrative
The stent remains in the patient.Investigation is not yet complete.A follow up report will be submitted with all additional relevant information.
 
Event Description
Patient id: (b)(6).It was reported that the procedure was performed to treat a lesion in the mid left anterior descending (lad) artery.The 3.0 x 23 mm xience sierra stent delivery system was advanced and the stent was implanted without issue.Post procedure, the patient experienced chest pain.Electrocardiogram (ekg) changes were noted.The patient was hypertensive and trace pericardial effusion was noted.Medication was administered as treatment.The adverse event resolved and the patient was discharged the following day.No additional information was provided.
 
Manufacturer Narrative
The device was not returned for evaluation.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.The reported patient effects of angina, hypertension and pericardial effusion are listed in the xience sierra everolimus eluting coronary stent systems instructions for use as known patient effects of coronary procedures.A conclusive cause for the reported patient effects, and the relationship to the product, if any, cannot be determined.However, the treatment appears to be related to the operational context of the procedure.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE SIERRA EVEROLIMUS ELUTING CORONARY STENT SYSTEM
Type of Device
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
MDR Report Key10840289
MDR Text Key216311872
Report Number2024168-2020-09530
Device Sequence Number1
Product Code NIQ
UDI-Device Identifier08717648227271
UDI-Public08717648227271
Combination Product (y/n)Y
PMA/PMN Number
P110019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,study
Type of Report Initial,Followup
Report Date 12/21/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date12/17/2021
Device Model Number1550300-23
Device Catalogue Number1550300-23
Device Lot Number0060941
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 10/22/2020
Initial Date FDA Received11/13/2020
Supplement Dates Manufacturer Received12/04/2020
Supplement Dates FDA Received12/21/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age76 YR
Patient Weight94
-
-