Model Number 3851
Device Problems Material Rupture (1546); Failure to Advance (2524)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 11/10/2020
Event Type  malfunction  
Manufacturer Narrative
Age at time of event: 18 years or older.(b)(6).
 
Event Description
It was reported that a balloon rupture occurred.The 75% stenosed target lesion was located in the moderately tortuous and moderately calcified mid left anterior descending artery.A 10mmx3.00mm wolverine coronary cutting balloon was selected for use.During procedure, the balloon was extremely difficult to insert into the lesion.After the balloon was able to cross the lesion, it was inflated at 8atm on second inflation and at 12atm on third inflation.However, it was noted that the balloon ruptured.The procedure was completed with a different device.No patient complications were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WOLVERINE CORONARY CUTTING BALLOON MONORAIL
Type of Device
CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key10925952
MDR Text Key218924662
Report Number2134265-2020-15898
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 11/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/01/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/07/2022
Device Model Number3851
Device Catalogue Number3851
Device Lot Number0025828753
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/10/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/07/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
GUIDE CATHETER: 6F HEARTRAIL JL3.5; GUIDEWIRE: SION BLUE; IMAGING CATHETER: OPTICROSS; INFLATION DEVICE: ABOTT 20/30; INTRODUCER SHEATH: 6F RADIFOCUS
-
-