• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ORTHO-CLINICAL DIAGNOSTICS VITROS IMMUNODIAGNOSTIC PRODUCTS ANTI-SARS-COV2 TOTAL REAGENT; IN VITRO DIAGNOSTICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ORTHO-CLINICAL DIAGNOSTICS VITROS IMMUNODIAGNOSTIC PRODUCTS ANTI-SARS-COV2 TOTAL REAGENT; IN VITRO DIAGNOSTICS Back to Search Results
Catalog Number 6199922
Device Problem False Negative Result (1225)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/30/2020
Event Type  malfunction  
Manufacturer Narrative
The investigation determined that a discordant negative vitros anti- sars-cov-2 total results were obtained from three patient samples processed using vitros cov2tot reagent lot 0220 on a vitros 3600 immunodiagnostic system.An assignable cause was not determined.The patients had all previously tested pcr positive approximately 2-4 weeks prior to vitros testing.It would be expected that the vitros cov2tot would be reactive as this assay detects the presence of igm, iga, and igg antibodies.No additional testing was performed to confirm or rule out the presence of an interferent in these patient samples.A review of historical quality control results for vitros cov2tot lot 0220 indicates acceptable performance and a reagent issue is not a likely contributor to the event.Additionally, ongoing tracking and trending of complaint data has not identified any signals to suggest there is a systemic quality issue with vitros cov2tot reagent lots 0220.Unexpected instrument performance is not a likely contributor to the events.However, it cannot be entirely ruled out as a contributing factor as precision testing to assess instrument performance was not performed by the customer when requested.The customer provided no information concerning the sample collection device used to collect the affected samples or sample processing of the affected samples.Therefore, pre-analytical sample handling cannot be ruled out as a potential contributor to this event.(b)(4).
 
Event Description
The customer reported that discordant negative vitros anti- sars-cov-2 total results were obtained from three patient samples processed using vitros cov2tot reagent lot 0220 on a vitros 3600 immunodiagnostic system.Patient 1 vitros cov2tot = 0.45 s/c (non-reactive) versus expected reactive.Patient 2 vitros cov2tot = 0.74 s/c (non-reactive) versus expected reactive.Patient 3 vitros cov2tot = 0.07 s/c (non-reactive) versus expected reactive.Biased results of the magnitude and direction observed may lead to inappropriate physician action if they were to occur undetected.The vitros results were not used for diagnostic purposes but patients were monitored for a period after a positive pcr result.There was no known treatment information for these patients.Ortho was not made aware of any allegation of patient harm as a result of this event.This report is number 2 of 3 mdr¿s for this event.Three (3) 3500a forms are being submitted for this event as three devices were involved.This report corresponds to ortho clinical diagnostics inc.Complaint numbers (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VITROS IMMUNODIAGNOSTIC PRODUCTS ANTI-SARS-COV2 TOTAL REAGENT
Type of Device
IN VITRO DIAGNOSTICS
Manufacturer (Section D)
ORTHO-CLINICAL DIAGNOSTICS
100 indigo creek drive
rochester NY 14626
Manufacturer (Section G)
ORTHO CLINICAL DIAGNOSTICS
felindre meadows
pencoed
bridgend, wales CF35 5PZ
UK   CF35 5PZ
Manufacturer Contact
joseph falvo
100 indigo creek drive
rochester, NY 14626
5854533000
MDR Report Key11002446
MDR Text Key221893565
Report Number3007111389-2020-00205
Device Sequence Number1
Product Code QKO
Combination Product (y/n)N
Reporter Country CodeRO
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,other
Reporter Occupation Other
Type of Report Initial
Report Date 12/14/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/14/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date03/03/2021
Device Catalogue Number6199922
Device Lot Number0220
Was Device Available for Evaluation? Yes
Date Manufacturer Received11/20/2020
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/03/2020
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-