Model Number TJF-260V
Device Problem Device Contamination with Chemical or Other Material (2944)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Type  malfunction  
Manufacturer Narrative
Since the subject device has been not returned to omsc for the evaluation, the exact cause of the reported event could not be conclusively determined at this time.If additional information becomes available, this report will be supplemented.
 
Event Description
Olympus medical systems corp.(omsc) was informed that it was found the dirt inside the light guide lens of the subject device during the incoming inspection for the repair at olympus (b)(4).There was no patient injury associated with this report.
 
Manufacturer Narrative
This supplemental report is being submitted to provide additional information.The subject device was not returned to olympus medical systems corp.(omsc) for evaluation but returned to olympus korea.The evaluation confirmed that crack on the light guide (lg) lens, a brown part inside the lg lens, and traces of fluid invasion.Omsc surmised that there was a gap in the adhesive around the lg lens, and fluid entered through around the lg lens.Omsc reviewed the manufacture history (dhr) of the subject device and confirmed no irregularity.The exact cause of the reported phenomenon could not be conclusively determined.However, based upon the past similar cases, there was the possibility that the reported phenomenon was attributed to physical stress, chemical stress, storage environment (such as direct sunlight, high temperature, high humidity, environment exposed to x-rays / ultraviolet rays, etc.), or aging deterioration.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVIS LUCERA DUODENOVIDEOSCOPE
Type of Device
DUODENOVIDEOSCOPE
Manufacturer (Section D)
OLYMPUS MEDICAL SYSTEMS CORP.
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8 507
JA  192-8507
MDR Report Key11043501
MDR Text Key225929602
Report Number8010047-2020-10712
Device Sequence Number1
Product Code FDT
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/30/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Model NumberTJF-260V
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 11/30/2020
Initial Date FDA Received12/20/2020
Supplement Dates Manufacturer Received01/18/2021
Supplement Dates FDA Received01/29/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-