SIEMENS HEALTHCARE DIAGNOSTICS, INC. ADVIA CENTAUR XP SARS-COV-2 TOTAL (COV2T); SARS-COV-2 IMMUNOASSAY Back to Search Results
Model Number N/A
Device Problem False Positive Result (1227)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/27/2020
Event Type  malfunction  
Manufacturer Narrative
The ifu states in the limitations section: "this assay should not be used to diagnose or exclude acute infection.Results are not intended to be used as the sole basis for patient management decisions.Test results should be interpreted in conjunction with clinical observations, patient history, epidemiological information, and other laboratory findings.A reactive test result does not exclude past or present infection by other coronaviruses, such as sars-cov-1, mers-cov, hku1, 229e, nl63, or oc43." a false positive/reactive result would not be used in isolation and would be correlated with clinical history.Additional laboratory testing would be used to determine specific antibody presence.Although there is no potential for serious injury in this case, an mdr will be reported to the fda as a requirement of the emergency use authorization (eua).Siemens healthcare diagnostics is investigating.Mdrs 1219913-2020-00668, and 1219913-2020-00669 were filed for false positive results generated on the same system and reagent lot on different test dates.
 
Event Description
The customer obtained reactive (positive) advia centaur xp sars-cov-2 total (cov2t) results for samples from ten patients.The reactive (positive) results were considered discordant with the negative results obtained when testing more than one replicate of the sample for each patient.There are no reports of patient intervention or adverse health consequences due to the discordant cov2t results.
 
Manufacturer Narrative
Siemens filed the initial mdr 1219913-2020-00667 on december 28, 2020.January 08, 2021 additional information: siemens healthcare diagnostics has concluded its investigation of atellica im and advia centaur sars-cov-2 total (cov2t) non-reproducible false reactive results with kit lots ending in 004, 005, 035 and 006.Siemens investigation determined that although non-reproducible false reactive results were observed with multiple kit lots, results indicate the negative percent agreement confidence interval of the kit lots evaluated overlap the confidence interval in the ifu; therefore they are performing within claims and a change in performance has not been confirmed.The ifu states in the limitations section: "this assay should not be used to diagnose or exclude acute infection.Results are not intended to be used as the sole basis for patient management decisions.Test results should be interpreted in conjunction with clinical observations, patient history, epidemiological information, and other laboratory findings.A reactive test result does not exclude past or present infection by other coronaviruses, such as sars cov-1, mers-cov, hku1, 229e, nl63, or oc43." a false positive/reactive result would not be used in isolation and would be correlated with clinical history.Additional laboratory testing would be used to determine specific antibody presence.The advia centaur xp sars-cov-2 total (cov2t) lot 006 is performing as intended.A product performance issue has not been identified.No further evaluation of the device is required.Mdrs 1219913-2020-00667 supplemental report 1, 1219913-2020-00668 supplemental report 1, and 1219913-2020-00669 supplemental report 1 were filed for false positive results generated on the same system and reagent lot on different test dates.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVIA CENTAUR XP SARS-COV-2 TOTAL (COV2T)
Type of Device
SARS-COV-2 IMMUNOASSAY
Manufacturer (Section D)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
511 benedict avenue
tarrytown NY 10591 5097
Manufacturer (Section G)
SIEMENS HEALTHCARE DIAGNOSTICS, INC.
333 coney street
e. walpole MA 02032
Manufacturer Contact
eiman sulieman
333 coney street
e. walpole, MA 02032
5086604603
MDR Report Key11077005
MDR Text Key242374210
Report Number1219913-2020-00667
Device Sequence Number1
Product Code QKO
Combination Product (y/n)N
Reporter Country CodeUK
PMA/PMN Number
EUA201370
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 01/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/28/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/02/2021
Device Model NumberN/A
Device Catalogue Number11206922
Device Lot Number006
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/08/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/16/2020
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-