BOSTON SCIENTIFIC CORPORATION DYNAGEN CRT-D; DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER, WITH CRT-D Back to Search Results
Model Number G151
Device Problems Signal Artifact/Noise (1036); High impedance (1291); Over-Sensing (1438); Noise, Audible (3273)
Patient Problems No Known Impact Or Consequence To Patient (2692); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/03/2020
Event Type  malfunction  
Event Description
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) emitted beep tones as the device recorded intermittent high, out of range left ventricular (lv) lead impedance measurements.In addition, noise was oversensed, and the company representative questioned if loss of capture (loc) occurred.Technical services (ts) discussed troubleshooting options.This crt-d and lv lead remain in service.No adverse patient effects were reported.
 
Event Description
Additional information was received which indicated that this lv was surgically abandoned and replaced.It was noted that the lead was fractured.The reported clinical observations are believed to be due to the lead fracture.This crt-d remains in service.No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DYNAGEN CRT-D
Type of Device
DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER, WITH CRT-D
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
MDR Report Key11104736
MDR Text Key224791643
Report Number2124215-2020-26993
Device Sequence Number1
Product Code NIK
UDI-Device Identifier00802526534638
UDI-Public00802526534638
Combination Product (y/n)N
PMA/PMN Number
P010012/S341
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Type of Report Initial,Followup
Report Date 02/21/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/02/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date10/08/2021
Device Model NumberG151
Device Catalogue NumberG151
Device Lot Number136710
Was Device Available for Evaluation? No
Date Manufacturer Received01/22/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age72 YR
-
-