Model Number 6623974
Device Problem Failure to Power Up (1476)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/04/2021
Event Type  malfunction  
Manufacturer Narrative
Siemens is conducting a thorough investigation of the reported events.As this event is under investigation, a root cause has not yet been determined.A supplement report will be filed upon completion of the investigation.
 
Event Description
It was reported to siemens that a malfunction occurred while operating the axiom sensis system.During an interventional procedure, the user reported no contact with the signal input box upon powering on.The procedure was continued and completed on an alternate system.We are unaware of any impact to the state of health of the patient involved.Siemens has requested additional information in order to conduct an investigation of the reported event.
 
Manufacturer Narrative
Siemens has completed an investigation of the reported event.Assessment does not indicate a system failure or malfunction and no non-conformity was identified.The detailed investigation showed that there was no malfunction of the system.The operation that took place did not correspond to the requirements of the system and was contrary to the procedure described in the instructions for use (ifu).It was clear from the log file that the shutdown sequence described in the ifu was not adhered to when the system was shut down the day before.As a result, the real-time computer (rtc) could not be booted the next time the device was switched on.In addition, the required system check was apparently not carried out before using the system, especially since the unavailability of the system was clearly indicated here.Our service department advised the customer by telephone and an orderly switch-off/on procedure immediately remedied the situation.The system works as specified.After detailed investigation, the incident is not classified as a reportable event as neither serious injury, death nor an unexpected prolonged hospitalization of the patient or any other person occurred or could be expected.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AXIOM SENSIS
Type of Device
COMPUTER, DIAGNOSTIC, PROGRAMMABLE
Manufacturer (Section D)
SIEMENS HEALTHCARE GMBH- AT
siemensstrasse 1
forchheim, germany 91301
GM  91301
MDR Report Key11164641
MDR Text Key228841446
Report Number3004977335-2021-62321
Device Sequence Number1
Product Code DQK
Combination Product (y/n)N
PMA/PMN Number
K150493
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Remedial Action Repair
Type of Report Initial,Followup
Report Date 01/13/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number6623974
Was Device Available for Evaluation? Yes
Initial Date Manufacturer Received 01/04/2021
Initial Date FDA Received01/13/2021
Supplement Dates Manufacturer Received02/18/2021
Supplement Dates FDA Received02/18/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-