• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CAREFUSION SD 8120 ALARIS PCA; PUMP, INFUSION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CAREFUSION SD 8120 ALARIS PCA; PUMP, INFUSION Back to Search Results
Model Number 8120
Device Problems Break (1069); Crack (1135); Failure to Analyze Signal (1539); Device Markings/Labelling Problem (2911); Appropriate Term/Code Not Available (3191)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
The customer reported problem was confirmed.The device was repaired, passed all require testing and specifications and released back to the customer.A review of the device history record in sap for sn (b)(4) was performed from the date of the manufacture to date of the release of product, which confirmed that this device was not involved in a production failure, and product was returned for servicing which correlates to the customer reported issue.A trackwise complaint history review was completed, and it was confirmed that there were additional complaints received with similar sn (b)(4) for the same or related failure mode.The customer stated that there is no patient involvement.
 
Event Description
Fails plunger pos accy test- (b)(4).Linear potentiometer- faulty.Case rear- damaged/cracked.Barrel clamp assy- damaged/cracked.Handle- damaged/cracked.Case front- damaged/cracked.Label- damaged.Iui- damaged pin.Iui- isolation rib damage.There was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
8120 ALARIS PCA
Type of Device
PUMP, INFUSION
Manufacturer (Section D)
CAREFUSION SD
10020 pacific mesa blvd
san diego CA 92121 4386
Manufacturer (Section G)
CAREFUSION SD
10020 pacific mesa blvd
san diego CA 92121 4386
Manufacturer Contact
lakshmanan bhoopalan
10020 pacific mesa blvd
san diego, CA 92121-4386
8586172000
MDR Report Key11213109
MDR Text Key228243431
Report Number2016493-2021-14839
Device Sequence Number1
Product Code MEA
UDI-Device Identifier10885403812002
UDI-Public10885403812002
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K043299
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 04/16/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number8120
Device Catalogue Number8120
Was Device Available for Evaluation? Yes
Initial Date Manufacturer Received Not provided
Initial Date FDA Received01/22/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured06/24/2010
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-