Model Number PRD-SC30-MICRO
Device Problem Entrapment of Device (1212)
Patient Problem Perforation of Vessels (2135)
Event Date 02/25/2021
Event Type  Injury  
Manufacturer Narrative
The results of the investigation are inconclusive since the reported device was not returned for analysis.Based on the information received, the cause of the reported event could not be conclusively determined.The device history record for this oad lot number has been reviewed.No issues or discrepancies were noted during this review that would have contributed to the reported event.The device met material, assembly, and quality control requirements.Csi id# (b)(4).
 
Event Description
A stealth peripheral orbital atherectomy device (oad) was selected for treatment of a 80-90% stenosed lesion in the dorsalis pedis accessed via a dorsalis pedis access.The lesion was moderately to severely calcified.The vessel was 2.0-2.5mm in diameter and moderately tortuous.The lesion was wired, and, during the second treatment, the oad stalled, and the oad was pulled back quickly.It was suspected that the vessel spasmed, which led to the device becoming stuck in the vessel.The lesion was treated with balloon angioplasty for three minutes.Angiography was performed, and a perforation was observed proximal to where the crown seized.Additional balloon angioplasty was performed for greater than 15 minutes.Imaging revealed residual extravasation, and an external hemostasis device was applied.The patient was stable following the procedure.It was unknown if the oad caused or contributed to the perforation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
STEALTH PERIPHERAL ORBITAL ATHERECTOMY SYSTEM
Type of Device
PERIPHERAL ATHERECTOMY DEVICE
Manufacturer (Section D)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer (Section G)
CARDIOVASCULAR SYSTEMS, INC.
1225 old highway 8 nw
saint paul MN 55112
Manufacturer Contact
sarah hicks
1225 old highway 8 nw
saint paul, MN 55112
MDR Report Key11476496
MDR Text Key239697638
Report Number3004742232-2021-00076
Device Sequence Number1
Product Code MCW
UDI-Device Identifier10850000491264
UDI-Public(01)10850000491264(17)220731(10)337308
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K190634
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 03/12/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date07/31/2022
Device Model NumberPRD-SC30-MICRO
Device Catalogue Number7-10059-01
Device Lot Number337308
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/25/2021
Initial Date FDA Received03/12/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured07/23/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age74 YR
Patient Weight74
-
-