• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SYNTHES GMBH UNK - PLATES; PLATE,FIXATION,BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SYNTHES GMBH UNK - PLATES; PLATE,FIXATION,BONE Back to Search Results
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Neuropathy (1983); Pain (1994)
Event Type  Injury  
Manufacturer Narrative
This report is for an unknown plate/unknown lot.Part and lot numbers are unknown; udi number is unknown.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
This report is being filed after the review of the following journal article: bain, g.I., galley, i.J., keogh, a.R.E., and durrant, a.W.(2010), axillary artery pseudoaneurysm after plate osteosynthesis for a clavicle nonunion: a case report and literature review, international journal of shoulder surgery, vol.4 (3), pages 79¿82 (australia).This study presents a case report of a (b)(6) year-old male patient who sustained a closed fracture to his nondominant left clavicle in 1998.He was treated non-operatively and went on to develop a symptomatic nonunion.Open reduction and bone grafting of the nonunion was performed in 1999 with a six-hole ao small fragment dynamic compression plate (dcp) (synthes).The clavicle united and his symptoms resolved.He presented 6 years after his surgery, with 18 months of progressively worsening pain, paraesthesia and claudication in his left hand.In the week prior to presentation, he noticed that his left hand was cool and pale.Clinically, he had a well-healed scar over his left clavicle with no associated mass or bruit.His left axillary artery was palpable.However, his brachial, radial and ulnar arteries were not.He had pain in the hand with exertion and poor capillary return.There were no trophic changes.His upper limb neurology was normal.Plain radiographs demonstrated a united clavicle with a six-hole plate superiorly.The medial screw was prominent inferiorly [figure 1].An arteriogram demonstrated the medial screw penetrating the axillary artery with an associated pseudoaneurysm [figure 2].There was occlusion of the brachial artery above the elbow [figure 3] with slow filling of the ulnar artery via collateral vessels.The radial artery and the proximal one-third of the ulnar artery were occluded.There was little flow past the metacarpophalangeal (mcp) joints.A computed tomography (ct) arteriogram confirmed penetration of the axillary artery by the prominent medial screw, with an associated pseudoaneurysm [figures 4 and 5].The patient was anticoagulated following plate removal [figure 6].The prominent medial screw measured 26 mm.The pseudoaneurysm was bypassed using a stent placed in the axillary artery via a femoral approach.The self-expanding stent is constructed with a durable, reinforced biocompatible, expanded polytetrafluoroethylene (eptfe) liner attached to the external nitinol stent structure.The stent was dilated using a 7 mm×40 mm balloon [figure 7].This report is for an unknown synthes dynamic compression plate.This is report 1 of 2 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNK - PLATES
Type of Device
PLATE,FIXATION,BONE
Manufacturer (Section D)
SYNTHES GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
Manufacturer Contact
kara ditty-bovard
1302 wrights lane east
west chester, PA 19380
6103142063
MDR Report Key11554892
MDR Text Key257205196
Report Number8030965-2021-02206
Device Sequence Number1
Product Code HRS
Combination Product (y/n)N
Reporter Country CodeAS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 02/24/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/24/2021
Initial Date FDA Received03/23/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age32 YR
-
-