• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC DE COSTA RICA S.R.L. POLARSHEATH

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC DE COSTA RICA S.R.L. POLARSHEATH Back to Search Results
Model Number M004CRBS3050
Device Problems Leak/Splash (1354); Material Integrity Problem (2978)
Patient Problems Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/25/2021
Event Type  malfunction  
Manufacturer Narrative
The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.To reduce the potential for air ingress into the sheath and the risk of embolism, the polarsheath instructions for use (ifu) was revised to emphasize best practices during use of this device.On april 13, 2021, boston scientific issued a field safety notice (92688876-fa) to communicate these ifu updates to all global customers in the interest of minimizing the risk of air embolism and promoting consistent use of the ifu in all geographies.
 
Event Description
It was reported that during a procedure involving a polarsheath device the cap on back of the handle detached.When a balloon catheter that was inserted though the polarsheath was removed, the valve of the sheath began to leak.The polarsheath could not be used to continue with rf (radiofrequency) ablation.No patient complications were reported.This product is part of the 92688876-fa advisory population for the polarsheath steerable sheath.
 
Manufacturer Narrative
To reduce the potential for air ingress into the sheath and the risk of embolism, the polarsheath instructions for use (ifu) was revised to emphasize best practices during use of this device.On april 13, 2021, boston scientific issued a field safety notice (92688876-fa) to communicate these ifu updates to all global customers in the interest of minimizing the risk of air embolism and promoting consistent use of the ifu in all geographies.Device technical analysis visual inspection of the device showed the end cap of the sheath was detached and not returned with device.There were no obvious tears/punctures appearing on the outer slit of the hemostatic.The device passed both the normal and extensive engineering aspiration and hemostasis testing.The device also passed the air pressure test for leaks.The manufacturing batch record review confirmed that the device met all material, assembly and performance specifications.Based on the information provided, there is no evidence that the device was used in a manner inconsistent with the labelled indications/instructions for use.
 
Event Description
It was reported that during a procedure involving a polahsheath device the cap on back of the handle detached.When a balloon catheter that was inserted though the polarsheath was removed, the valve of the sheath began to leak.The polarsheath could not be used to continue with rf (radiofrequency) ablation.No patient complications were reported.This product is part of the 92688876-fa advisory population for the polarsheath steerable sheath.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POLARSHEATH
Manufacturer (Section D)
BOSTON SCIENTIFIC DE COSTA RICA S.R.L.
302 parkway
global park, la aurora
heredia
CS 
MDR Report Key11711980
MDR Text Key249325332
Report Number2134265-2021-05174
Device Sequence Number1
Product Code DRA
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Remedial Action Notification
Type of Report Initial,Followup
Report Date 07/07/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date09/13/2021
Device Model NumberM004CRBS3050
Device Lot Number0026287706
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/18/2021
Initial Date Manufacturer Received 03/26/2021
Initial Date FDA Received04/22/2021
Supplement Dates Manufacturer Received06/09/2021
Supplement Dates FDA Received07/07/2021
Removal/Correction Number92688876-FA
Patient Sequence Number1
-
-