MEDTRONIC IRELAND RESOLUTE ONYX RX; CORONARY DRUG-ELUTING STENT Back to Search Results
Catalog Number RONYX22526UX
Device Problems Activation, Positioning or Separation Problem (2906); Device Damaged by Another Device (2915)
Patient Problem Unspecified Tissue Injury (4559)
Event Date 05/18/2021
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
During a procedure, attempt was made to implant one resolute onyx rx coronary drug eluting stent to treat a mildly tortuous and moderately calcified lesion in the mid cx artery with 95% stenosis.The device was inspected with no issues noted.The device was prepped per ifu with no issues noted.Negative prep was performed with no issues noted.It was noted that the vessel was an anomalous circumflex which arose from the aorta.The lesion was predilated.The device did pass through a previously resolute onyx des deployed stent.Resistance was encountered when advancing the device.Excessive force was used during delivery.It was reported that a stent dislodgement occurred during delivery to/at lesion.The dislodged stent was dilated against the ostial/proximal wall of the artery with a coronary balloon.It was informed that the stent dislodgement occurred due to the struts becoming entangled with the struts of a previously deployed resolute onyx des stent.Once entangled, the removal of the delivery system resulted in the stent remaining at the ostial portion of the anomalous circumflex.The physician believes that the previously deployed resolute onyx des may not have been optimally opposed to the arterial wall and the subsequently delivered stent caught on a strut.The entire segment dilated with a balloon after becoming entangled with the dislodged resolute onyx des, and has remained implanted.The patient is alive with no further injury reported.
 
Manufacturer Narrative
Additional information: annex d, annex g code added.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESOLUTE ONYX RX
Type of Device
CORONARY DRUG-ELUTING STENT
Manufacturer (Section D)
MEDTRONIC IRELAND
parkmore business park west
galway
EI 
MDR Report Key11997709
MDR Text Key256155585
Report Number9612164-2021-02300
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)N
PMA/PMN Number
P160043
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 06/30/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/03/2022
Device Catalogue NumberRONYX22526UX
Device Lot Number0010265334
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 05/25/2021
Initial Date FDA Received06/15/2021
Supplement Dates Manufacturer Received06/17/2021
06/24/2021
Supplement Dates FDA Received06/29/2021
06/30/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age71 YR
Patient Weight54
-
-