ON-X LIFE TECHNOLOGIES, INC. ON-X AORTIC VALVE UNKNOWN CONFIGURATION; HEART-VALVE MECHANICAL
|
Back to Search Results |
|
Model Number ONXA UNK |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Endocarditis (1834); Hemorrhage/Bleeding (1888); Thromboembolism (2654)
|
Event Type
Injury
|
Event Description
|
According to the initial report received via email on 07-june-2021 the presentation by kim js, kang y, shon sh, choi jw, hwang hy, kim kh.Long-term clinical outcome of on-x mechanical prosthetic valve in aortic and mitral position: a single center experience with 20 years follow-up results, presentation #000266 at 34theacts, barcelona, spain 2020 oct 8-10.The purpose of the study was to evaluate the long-term outcome of the on-x valve implanted in the left side of the heart for up to 20 years of follow-up.This was a single-center retrospective study of 861 on-x only recipients operated between february 1999 to december 2015.There were 344 avr, 325 mvr, and 192 double valve replacement (dvr) cases.Males dominated the aortic cases (63.1%) while females dominated the mitral (67.1%).Dvr was almost evenly split.Mean clinical follow-up was 10.1 ± 5.2 years for a cumulative follow-up of 8405.8 patient-years.Combined total results include 0.6%/pt-year of bleeding, 0.8%/pt-year of thromboembolism, 0.2%/pt-year of endocarditis, and 0.5%/pt-year of non-structural valve deterioration.This study also includes the on-x mitral valve: onxm unk.
|
|
Event Description
|
According to the initial report received via email on 07-june-2021 the presentation by kim js, kang y, shon sh, choi jw, hwang hy, kim kh.Long-term clinical outcome of on-x mechanical prosthetic valve in aortic and mitral position: a single center experience with 20 years follow-up results, presentation #000266 at 34theacts, barcelona, spain 2020 oct 8-10.The purpose of the study was to evaluate the long-term outcome of the on-x valve implanted in the left side of the heart for up to 20 years of follow-up.This was a single-center retrospective study of 861 on-x only recipients operated between february 1999 to december 2015.There were 344 avr, 325 mvr, and 192 double valve replacement (dvr) cases.Males dominated the aortic cases (63.1%) while females dominated the mitral (67.1%).Dvr was almost evenly split.Mean clinical follow-up was 10.1 ± 5.2 years for a cumulative follow-up of 8405.8 patient-years.Combined total results include 0.6%/pt-year of bleeding, 0.8%/pt-year of thromboembolism, 0.2%/pt-year of endocarditis, and 0.5%/pt-year of non-structural valve deterioration.This study also includes the on-x mitral valve: onxm unk.
|
|
Search Alerts/Recalls
|
|
|