U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ST. JUDE MEDICAL, COSTA RICA LTDA TRIFECTA STENTED TISSUE VALVE; HEART-VALVE, NON-ALLOGRAFT TISSUE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ST. JUDE MEDICAL, COSTA RICA LTDA TRIFECTA STENTED TISSUE VALVE; HEART-VALVE, NON-ALLOGRAFT TISSUE Back to Search Results
Device Problems Biocompatibility (2886); Insufficient Information (3190)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/16/2021
Event Type  Injury  
Manufacturer Narrative
The results, method, and conclusion codes along with investigation results will be provided in the final report.
 
Event Description
It was reported that in 2018, a tissue heart valve was implanted.On (b)(6) 2021, the valve had failed and was explanted.The device was replaced with a competitor valve to resolve the event.The patient remained hemodynamically stable throughout the procedure, is stable and doing well.No additional information was provided.
 
Manufacturer Narrative
Additional information: d1, d3, g1.
 
Manufacturer Narrative
Explant was reported due to the valve having "failed".The investigation found that there was circumferential fibrous pannus ingrowth on the inflow and outflow surfaces of the valve which limited the leaflet mobility and narrowed the inflow diameter.No acute inflammation or significant calcifications were present.While the exact reason for valve explant remains unknown, the pannus ingrowth impeding leaflet mobility and narrowing the inflow diameter could lead to a number of potential issues with valve functionality.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIFECTA STENTED TISSUE VALVE
Type of Device
HEART-VALVE, NON-ALLOGRAFT TISSUE
Manufacturer (Section D)
ST. JUDE MEDICAL, COSTA RICA LTDA
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 01897 -405
CS  01897-4050
Manufacturer (Section G)
ST. JUDE MEDICAL, COSTA RICA LTDA
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 01897 -405
CS   01897-4050
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key12155463
MDR Text Key264388981
Report Number3001883144-2021-00107
Device Sequence Number1
Product Code LWR
Combination Product (y/n)N
Reporter Country CodeAS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 11/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/21/2021
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/16/2021
Initial Date FDA Received07/12/2021
Supplement Dates Manufacturer Received08/18/2021
10/28/2021
Supplement Dates FDA Received08/31/2021
11/15/2021
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-