BOSTON SCIENTIFIC CORPORATION SMALL PERIPHERAL CUTTING BALLOON; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number 24658
Device Problem Failure to Advance (2524)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/25/2021
Event Type  malfunction  
Manufacturer Narrative
(b)(6).Device evaluated by mfr.: the device was returned for analysis.A visual examination of the returned device identified that the balloon had been inflated and was not refolded.It is not known when the balloon was subjected to positive pressure.The balloon and blades of the device were visually and microscopically examined, and no issues were noted that may have potentially contributed to the complaint incident.All blades were present and fully bonded to the balloon surface.A visual and microscopic examination observed no damage to the tip.A visual and tactile examination identified a shaft break 455mm distal of the distal end of the strain relief.There were multiple hypotube kinks along the length of the hypotube.No other issues were identified during the product analysis.
 
Event Description
Reportable based on device analysis completed on 28jul2021.It was reported that crossing difficulties were encountered.The 99% stenosed target lesion was located in the severely tortuous and severely calcified posterior tibial artery.A 2.50mm/1.5cm/140cm small peripheral cutting balloon was selected for use but was unable to cross the lesion.The procedure was completed with a different device.No patient complications were reported.However, returned device analysis revealed shaft break.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SMALL PERIPHERAL CUTTING BALLOON
Type of Device
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key12348411
MDR Text Key267468096
Report Number2134265-2021-10489
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeJA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 08/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/20/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/13/2023
Device Model Number24658
Device Catalogue Number24658
Device Lot Number0025854527
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/12/2021
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/28/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured08/13/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-