PRISMATIK DENTALCRAFT, INC. COMFORT HARD-SOFT SPLINT; THERMOFORM MOUTHGUARD Back to Search Results
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Hypersensitivity/Allergic reaction (1907)
Event Type  Injury  
Manufacturer Narrative
The device has been returned.Once the investigation is complete a supplemental report will be submitted.The patients weight is not provided as it is not taken at the time of appointment.With the exception of serial number as the device is manufactured by prescription.The device is manufactured by prescription and not implantable.
 
Event Description
It was reported that the patient had a reaction to the comfort hard-soft splint device.It was reported that the appliance was worn at night on (b)(6) 2021 and noticed "possible reaction within a day." it is unclear of the exact day of the reaction per the provider but reported it to the provider on (b)(6) 2021.The patient noticed "red bumps near lips and cheek." once the patient discontinued the device, the reaction lasted 2-3 days after the discontinuation.The patient has no known allergies.With regard to the device: the provider sterilized (per manufacturer instructions) the device prior to delivery to the patient.The patient was advised to clean and store the device per "manufacturer instructions.".
 
Manufacturer Narrative
The device investigation has been completed and the results are as follows: dhr results: the dhr was reviewed and there was no evidence discovered to indicate that a product defect or non-conformity contributed to the issue.Supplier (erkodent) reviewed the associated material lot and confirmed no manufacturing deviation or abnormality.Lot# e-pro 3.0-11600 (erkoloc-pro) was manufactured from 03/29/21 with an expiration set to march, 2024.Stock product reviewed results: no stock product was available for review since the device was fabricated per physician's prescription only.Investigation methods/results: complaint investigator reviewed the returned device.A lower tray was returned in the original case.The results were summarized: roughness - the edge was smooth.Crack - no major crack was found.Delamination - layers were intact and did not separate.Discoloration - the device had a slight yellowish tint due to the usage.General cleanliness - the returned device appeared to be clean, free of debris or foreign particles.The returned device was visually inspected, and no defect or abnormality was observed.There was no evidence found to indicate that the reported issue was caused by the device itself.Root cause: a root cause for this complaint cannot be explicitly determined.Ifu 9091 rev 3.0 (comfort h/s bite splint instruction for use) states to use only clear, cool water to wash the device.Ifu provides warning "do not clean or soak in mouthwash; do not use denture cleanser, hot water, alcohol, hydrogen peroxide; do not place in direct sunlight".It is possible that reactions could be caused by mouthwash, toothpaste, or soaking material.Supplier erkodent reviewed the incident details and determined an allergic reaction could not be ruled out.Glidewell research team and namsa conducted a series of testing on a similar thermoformed sleep device following iso 10993 (biological evaluation of medical devices) and the device was evaluated for potential cytotoxicity, skin irritation, delayed dermal contact sensitization and oral mucosal irritation.The test article was thermoformed with layers of erkodent material (erkoloc-pro and erkodur).The test results were listed below and summarized in biocompatibility report for sleep device (rpt 9733 rev 1.0) · for cytotoxicity testing, the test article extract showed no evidence of causing cell lysis or toxicity.· for skin irritation, there was no erythema and no edema observed on the skin of the animals treated with the test article.· for sensitization testing, the test article extracts showed no evidence of causing delayed dermal contact sensitization.· the test article showed nonirritant to the oral mucosa as compared to the control article.The device materials have been found to be biocompatible through the testing.There was no cytotoxic, sensitization, skin irritation, or oral mucosal irritation found in any of the test articles.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COMFORT HARD-SOFT SPLINT
Type of Device
THERMOFORM MOUTHGUARD
Manufacturer (Section D)
PRISMATIK DENTALCRAFT, INC.
2144 michelson drive
irvine CA 92612
MDR Report Key12442768
MDR Text Key270414117
Report Number3011649314-2021-00311
Device Sequence Number1
Product Code MQC
Combination Product (y/n)N
PMA/PMN Number
K121365
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 09/27/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/08/2021
Initial Date Manufacturer Received 08/13/2021
Initial Date FDA Received09/08/2021
Supplement Dates Manufacturer Received09/16/2021
Supplement Dates FDA Received09/27/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age28 YR
-
-