MAUDE Adverse Event Report: STRYKER NEUROVASCULAR CORK NEUROFORM ATLAS 3.0MM X 24MM NO TIP- IDE; STENT, INTRACRANIAL NEUROVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER NEUROVASCULAR CORK NEUROFORM ATLAS 3.0MM X 24MM NO TIP- IDE; STENT, INTRACRANIAL NEUROVASCULAR Back to Search Results
Catalog Number M003SZAS30240C
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Stroke/CVA (1770); Dysphasia (2195)
Event Date 05/21/2017
Event Type  Injury  
Manufacturer Narrative
Device remains implanted in patient.
 
Event Description
It was reported during a clinical study that after implant of the stent (subject device) 1+ year post procedure the patient suffered aphasia, adjudicated as a minor ipsilateral ischemic stroke per the cec.It lasted less than 24 hours and resolved with residual effects.The treatment provided was medication.
 
Manufacturer Narrative
The subject device is not available; therefore, visual and functional testing as well as physical analysis cannot be performed.The reported complaint could not be confirmed, and it could not be definitively determined if the device failed to meet specifications because the product was not returned.The reported event is covered in the device directions for use (dfu).As well, the risk of the reported event is documented in the risk documentation and there are current controls to mitigate the risk of the as reported event.Due to the automated mes system there are controls in the manufacturing process to ensure the product met specifications upon release.An assignable cause of anticipated procedural complication will be assigned to the reported event of patient stroke as a product related root cause does not apply and the issue is due to a known physiological effect of the procedure and/or patient condition noted with the directions for use, product labeling and/or risk documentation files.H3 other text : device remains implanted in patient.
 
Event Description
It was reported during a clinical study that after implant of the stent (subject device) 1+ year post procedure the patient suffered aphasia, adjudicated as a minor ipsilateral ischemic stroke per the cec.It lasted less than 24 hours and resolved with residual effects.The treatment provided was medication.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEUROFORM ATLAS 3.0MM X 24MM NO TIP- IDE
Type of Device
STENT, INTRACRANIAL NEUROVASCULAR
Manufacturer (Section D)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI  NA
Manufacturer (Section G)
STRYKER NEUROVASCULAR CORK
ida industrial estate
model farm road
cork NA
EI   NA
Manufacturer Contact
tara lopez
47900 bayside parkway
fremont, CA 94538
5104132500
MDR Report Key12479047
MDR Text Key271658712
Report Number3008881809-2021-00381
Device Sequence Number1
Product Code NJE
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P180031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 12/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date08/31/2016
Device Catalogue NumberM003SZAS30240C
Device Lot Number18551391
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/25/2021
Initial Date FDA Received09/16/2021
Supplement Dates Manufacturer Received11/22/2021
Supplement Dates FDA Received12/20/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/11/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age65 YR
Patient SexFemale
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-