Catalog Number AASLE08080 |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Stenosis (2263)
|
Event Date 04/09/2021 |
Event Type
Injury
|
Manufacturer Narrative
|
As the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.(expiry date: 02/2022).Device not returned.
|
|
Event Description
|
It was reported that nine months post stent placement procedure through the right artery iliac externa via a crossover approach, the patient allegedly developed stenosis in the proximal part of the stent.The current status of the patient is unknown.
|
|
Event Description
|
It was reported that nine months post stent placement procedure through the right artery iliac externa via a crossover approach, the patient allegedly developed stenosis in the proximal part of the stent.The current status of the patient is unknown.
|
|
Manufacturer Narrative
|
H10: the catalog number identified in section d4 has not been cleared in the us but is similar to the covera plus vascular covered stent products that are cleared in the us.The pro code and 510 k number for the covera plus vascular covered stent products are identified in d2 and g4.H10: manufacturing review: a review of manufacturing records was not performed, as additional complaints have not been reported for this lot.Based on the information available it is not reasonably suggested that a manufacturing process may have caused or contributed to the reported issue.However, the lot history records of this lot were reviewed with special attention to the manufacturing and inspection of this product and the product was found to have met the specification prior to shipment.Investigation summary: the sample was not returned for evaluation and image was not provided.Based on the investigation of the provided information, the investigation is inconclusive.A definite root cause for the reported event could not be determined.Labeling review: in reviewing the relevant labeling, it was found that the instructions for use sufficiently address 'restenosis', and 'occlusion' under potential complications that may occur.The instructions for use further state: 'pre-dilate the stenosis with a pta balloon catheter of appropriate length and diameter for the lesion to be treated.', and 'post dilate the covered stent with an angioplasty balloon sized appropriately as to ensure complete wall apposition to the reference vessel.Avoid balloon dilation in the healthy, non-stenosed segment of the vessel.' holding and handling of the system throughout deployment was found sufficiently described.H10: (expiry date: 02/2022).H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text: device not returned.
|
|