U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BRUNO INDEPENDENT LIVING AIDS, INC. BRUNO; VERTICAL PLATFORM LIFT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BRUNO INDEPENDENT LIVING AIDS, INC. BRUNO; VERTICAL PLATFORM LIFT Back to Search Results
Model Number VPL-3175B
Device Problem Unintended Movement (3026)
Patient Problem Insufficient Information (4580)
Event Date 01/05/2022
Event Type  malfunction  
Manufacturer Narrative
Current dealer informed bruno of the incident on 01-05-2022.The current dealer in (b)(6) is not the installing dealer.The current dealer started supporting the unit in (b)(6) 2018.Bruno contacted the dealer on 01-5-2022 and arranged to send the chief engineer for the product line to conduct on-site for inspection.This inspection was delayed at end user's request to later in january.At the site, the chief engineer confirmed with the end user that there were no injuries as a result of this incident.The initial site investigation indicated that the main drive nut was worn to point of failure causing the platform to fall on the safety nut, as intended.The safety switch however did not engaged and thus allowed the unit to ride on safety nut.The safety nut then failed causing the unit to fail.This was the first time this type of nut safety switch engagement failure was observed.It was not possible to do a complete inspection on site.Parts were removed to continue the investigation at the manufacturer's facilities.This capa investigation to determine root cause is being conducted under the oversight of the director of engineering to determine reason(s) that may have prevented the safety switch from being activated.
 
Event Description
The event was described to the manufacturer third hand when reported on (b)(6)2022.The end user has a vpl-3175b (6ft or 75" travel) unit installed with an unenclosed exterior application that was installed in 2013.On (b)(6) 2021, a friend of the end user's adult daughter was operating the unit, standing on the platform, while it ascended.It was reported that the unit dropped without notice.There was conflicting information if the rider suffered a minor injury.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BRUNO
Type of Device
VERTICAL PLATFORM LIFT
Manufacturer (Section D)
BRUNO INDEPENDENT LIVING AIDS, INC.
1780 executive drive
oconomowoc WI 53066
Manufacturer (Section G)
BRUNO INDEPENDENT LIVING AIDS, INC.
1780 executive drive
oconomowoc WI 53066
Manufacturer Contact
william belson iii
1780 executive drive
oconomowoc, WI 53066
2629535359
MDR Report Key13460512
MDR Text Key287669815
Report Number2131358-2022-00002
Device Sequence Number1
Product Code ING
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K061514
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Distributor
Reporter Occupation Other Health Care Professional
Remedial Action Inspection
Type of Report Initial
Report Date 02/04/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model NumberVPL-3175B
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 01/05/2022
Initial Date FDA Received02/04/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/27/2013
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Age28 YR
Patient SexFemale
Patient Weight147 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-