Catalog Number FVM14120 |
Device Problems
Positioning Failure (1158); Fracture (1260)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 11/15/2021 |
Event Type
malfunction
|
Event Description
|
It was reported that during a stent placement procedure, the stent allegedly failed to deploy.There was no reported patient injury.
|
|
Manufacturer Narrative
|
The catalog number identified has not been cleared in the us, but is similar to the fluency plus endovascular stent graft products that are cleared in the us.The pro code and 510k number for the fluency plus endovascular stent graft products is identified.Manufacturing review: the lot history record of this lot was reviewed with special attention to the manufacturing and inspection of this product, and the product was found to have met the specification prior to shipment.Investigation summary: the sample was returned for evaluation.Based on the investigation performed in the laboratory, the fracture of the outer sheath could be determined as the main issue to the reported event.The failure to deploy issue could not be confirmed, since the stent was not found inside the sheath.Based on the investigation of the provided information, the investigation is confirmed for fracture.A definite root cause for the reported event could not be determined based upon the available information.Labeling review: in reviewing the relevant labeling, it was found that the instructions for use sufficiently address the potential risks.Regarding preparation of the device the instructions for use state that 'prior to loading the vascular system over a guide wire, both ports must be flushed with sterile saline (.).Flushing these lumens will also facilitate stent graft deployment.' regarding the anatomy of the placement site the instructions for use states: 'prior to stent graft deployment (.), ensure that the proximal stent graft end is positioned in a straight section of the lumen to reduce the risk of increased deployment forces and possible failure to deploy.' regarding accessories the instructions for use states: 'a super stiff guide wire (0.035 in.) is advanced from a femoral artery puncture site.Use an introducer sheath for the implant procedure'; the packaging pictograms indicate an introducer size of 10f and a 0.035" guidewire.(expiry date: 12/2022).
|
|
Manufacturer Narrative
|
The catalog number identified has not been cleared in the us, but is similar to the fluency plus endovascular stent graft products that are cleared in the us.The pro code and 510k number for the fluency plus endovascular stent graft products is identified.Manufacturing review: the lot history record of this lot was reviewed with special attention to the manufacturing and inspection of this product, and the product was found to have met the specification prior to shipment.Investigation summary: the sample was returned for evaluation.Based on the investigation performed in the laboratory, the fracture of the outer sheath could be determined as the main issue to the reported event.The failure to deploy issue could not be confirmed, since the stent was not found inside the sheath.Based on the investigation of the provided information, the investigation is confirmed for fracture.A definite root cause for the reported event could not be determined based upon the available information.Labeling review: in reviewing the relevant labeling, it was found that the instructions for use sufficiently address the potential risks.Regarding preparation of the device the instructions for use state that 'prior to loading the vascular system over a guide wire, both ports must be flushed with sterile saline (.).Flushing these lumens will also facilitate stent graft deployment.' regarding the anatomy of the placement site the instructions for use states: 'prior to stent graft deployment (.), ensure that the proximal stent graft end is positioned in a straight section of the lumen to reduce the risk of increased deployment forces and possible failure to deploy.' regarding accessories the instructions for use states: 'a super stiff guide wire (0.035 in.) is advanced from a femoral artery puncture site.Use an introducer sheath for the implant procedure'; the packaging pictograms indicate an introducer size of 10f and a 0.035" guidewire.(expiry date: 12/2022).
|
|
Event Description
|
It was reported that during a stent placement procedure, the stent allegedly failed to deploy.There was no reported patient injury.
|
|