Model Number M00535900 |
Device Problems
Break (1069); Material Deformation (2976)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 03/11/2022 |
Event Type
malfunction
|
Event Description
|
It was reported to boston scientific corporation that an ultratome xl was used in the papilla during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6) 2022.During the procedure, the physician inserted the device through the duodenoscope to perform sphincterotomy.When the device was energized, the "wire burst." it did not cause any damage to the patient.Additionally, no part of the cutting wire detached and fell into the patient.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be stable.
|
|
Manufacturer Narrative
|
(b)(4).The device has not been received for analysis.Upon receipt and completion of the problem analysis of the complaint device, if there is any further relevant information from that review, a supplemental medwatch will be filed.
|
|
Event Description
|
It was reported to boston scientific corporation that an ultratome xl was used in the papilla during an endoscopic retrograde cholangiopancreatography (ercp) procedure performed on (b)(6), 2022.During the procedure, the physician inserted the device through the duodenoscope to perform sphincterotomy.When the device was energized, the "wire burst." it did not cause any damage to the patient.Additionally, no part of the cutting wire detached and fell into the patient.The procedure was completed with another of the same device.There were no patient complications reported as a result of this event.The patient's condition at the conclusion of the procedure was reported to be stable.Note: a photo of the complaint device outside the patient was provided by the customer and shows the cutting wire was broken and kinked.
|
|
Manufacturer Narrative
|
Block h6 (device codes): medical device problem code a0401 captures the reportable event of cutting wire broken.Block h10: the returned ultratome xl was analyzed, and a visual evaluation noted that the cutting wire was broken and bent from the proximal pierced hole.The device was observed under magnification and the cutting wire was broken, bent, and blackened from the proximal pierced hole.These findings were consistent with the finding per media analysis based on the provided photo.No other problems with the device were noted.The reported event of cutting wire break was confirmed.Upon analysis, it was found that the cutting wire was broken, and blackened.The cutting wire being blackened indicates that the device was energized.Based on the condition of the device, the problem found could have been caused if the cutting wire was preactivated before use which can cause premature cutting wire fatigue and compromise the cutting wire's integrity.Also, not verifying that the cutting wire has exited the endoscope when electrical current is applied and not maintaining direct and constant contact with tissue when applying electrocautery current could contribute to wire breakage.Additionally, an excess of power could have damaged the integrity of cutting wire.Once the cutting wire breaks, any attempt to remove the device from the scope can lead to the broken section hitting the working channel of the scope.This can kink/bend the cutting wire.Based on all gathered information, the most probable root cause of this complaint is adverse event related to procedure.A review of the manufacturing documentation for this device revealed that no anomalies or deviations related to the event occurred during manufacturing.A labeling review was performed and, from the information available, this device was used per the instructions for use (ifu) / product label.
|
|