Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Pulmonary Embolism (1498); Thrombosis/Thrombus (4440)
|
Event Date 03/01/2022 |
Event Type
Injury
|
Manufacturer Narrative
|
Title: thrombotic complications after thermal and nonthermal endovenous ablation: outcomes of a multicenter real-world experience author: leigh ann o'banion, mariya kochubey, meghan tenet journal: journal of vascular surgery: venous and lymphatic disorders year: 2022 vol/issue: 10(2) ref: 10.1016/j.Jvsv.2021.12.013.Age: average age, gender: majority gender, date: date of publication, race: majority race in study population (other races also included are asian, black and hispanic).If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
A journal abstract was submitted detailing a study which aims to compare the incidence of endovenous heat-induced thrombosis (ehit) and endovenous glue-induced thrombosis (egit) in a large cohort of patients with chronic venous insufficiency (cvi).803 patients were included in the study.Medtronic¿s closurefast and venaseal devices were used in the study.There were 700 radiofrequency ablation (rfa) procedures and 396 venaseal procedures conducted.A combined closure rate of 98% was reported on postprocedure duplex.The incidence of ehit and egit was 1.9% and 1.3% respectively, and the deep vein thrombosis rate was 0.1% in the rfa cohort and 0.2% in the venaseal cohort.One case of pulmonary embolism diagnosed by computed tomography angiogram was reported in the rfa group.
|
|
Manufacturer Narrative
|
Additional information: relevant medical history provided.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Search Alerts/Recalls
|
|
|