DEPUY ORTHOPAEDICS INC US UNK HIP ACETABULAR LINER CERAMIC; CERAMIC ACETABULAR LINER Back to Search Results
Catalog Number UNK HIP ACETABULAR LINER CERAM
Device Problems Fracture (1260); Device Dislodged or Dislocated (2923); Migration (4003)
Patient Problems Pain (1994); Joint Dislocation (2374)
Event Date 01/18/2022
Event Type  Injury  
Manufacturer Narrative
Product complaint #
=
> (b)(4).Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Literature article entitled ¿long-term results of delta ceramic-on-ceramic total hip arthroplasty" written thomas j.Blumenfeld, md, joel politi, md, sean coker, tammy o¿dell, william hamilton, md.Published in arthroplasty today; published online 18 january 2022 was reviewed.The article's purpose was to report the minimum 10-year follow-up of both the 28-mm and 36-mm articulations concentrating on survivorship and bearing complications including fracture and squeaking.Patient data: patients aged 20 to 75 years undergoing primary tha for noninflammatory degenerative joint disease.Depuy products: pinnacle cementless porous coated cup; aml, prodigy, summit, porocoat, duofix, srom, or corail cementless stems.It is also reasonable to conclude the ceramic head and liner were also depuy product.Adverse events: (4) hip noise ¿ no treatment indicated (2) dislocation -treatment of 1 revision and 1 closed reduction (3) ceramic liner fracture ¿ treated with revision (1) pain ¿ treated with revision.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.This complaint was opened to document complaints derived through a journal article review.Follow-ups were done to try and obtain additional information from the author of the journal article.No further information was received.Device history lot: a manufacturing record evaluation (mre), was not possible because the required lot code was not provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNK HIP ACETABULAR LINER CERAMIC
Type of Device
CERAMIC ACETABULAR LINER
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
Manufacturer (Section G)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic dr.
warsaw IN 46581 0988
Manufacturer Contact
kate karberg
700 orthpaedic dr.
warsaw, IN 46581
3035526892
MDR Report Key14986352
MDR Text Key295686372
Report Number1818910-2022-12816
Device Sequence Number1
Product Code MRA
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Literature,Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 07/12/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP ACETABULAR LINER CERAM
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 06/22/2022
Initial Date FDA Received07/12/2022
Supplement Dates Manufacturer Received07/13/2022
Supplement Dates FDA Received07/14/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-