MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 PUREWICK FEMALE EXTERNAL CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 PUREWICK FEMALE EXTERNAL CATHETER Back to Search Results
Model Number PWFX30
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Urinary Tract Infection (2120); Hematuria (2558)
Event Date 06/21/2022
Event Type  Injury  
Event Description
It was reported that patient was using the purewick female external catheter and started peeing out blood.Stated that his had happened two days ago and the patient had stated it happens when they use the purewick urine collection system.User stated that there was a blood clot in urine initially and then observed blood after that.It was noted that the patient had using this product for a week only and less than 90 days.Per follow up received via phone on (b)(6) 2022, it was stated that the patient did seek medical treatment for the blood.The doctor determined that the patient had a urinary tract infection and prescribed medication.It was unknown what medication was provided for the urinary tract infection.
 
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Manufacturer Narrative
The reported event was inconclusive because no sample was returned.The potential root cause for this failure could be "inadequate material selection - materials of construction are not biocompatible or material surface is rough, abrasive or uncomfortable ".It is unknown whether the device had met relevant specifications.The product was used for treatment purposes.It was unknown whether the product had caused the reported failure.The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "setup: 1.Connect the canister to wall suction and set to a minimum of 40mmhg continuous suction.Always use the minimum amount of suction necessary.If using the drydoctm vacuum station, connect the canister to the unit and turn the unit on.Please consult the drydoctm vacuum station user guide for further information.2.Using standard suction tubing, connect the purewicktm female external catheter to the collection canister.Peri-care and placement: 3.Perform perineal care and assess skin integrity (document per hospital protocol).Separate legs, gluteus muscles, and labia.Palpate pubic bone as anatomical marker.4.With soft gauze side facing patient, align distal end of the purewicktm female external catheter at gluteal cleft.Gently tuck soft gauze side between separated gluteus and labia.Ensure that the top of the gauze is aligned with the pubic bone.Slowly place legs back together once the purewicktm female external catheter is positioned.Removal: 5.To remove the purewicktm female external catheter, fully separate the legs, gluteus, and labia.To avoid potential skin injury upon removal, gently pull the purewicktm female external catheter directly outward.Ensure suction is maintained while removing the purewicktm female external catheter.After use, this product may be a potential biohazard.Dispose of in accordance with applicable local, state and federal laws and regulations.Maintenance: 6.Replace the purewicktm female external catheter at least every 8-12 hours or if soiled with feces or blood.Always assess skin for compromise and perform perineal care prior to placement of a new purewicktm female external catheter.Note: patient can be positioned on back, side lying, frog legged, or lying on back with knees bent and thighs apart (lithotomy position) prior to device placement.Indication for use: the purewicktm female external catheter is intended for non-invasive urine output management in female patients.Contraindications: ¿ patients with urinary retention warnings: ¿ do not use the purewicktm female external catheter with bedpan or any material that does not allow for sufficient airflow.¿ to avoid potential skin injury, never push or pull the purewicktm female external catheter against the skin during placement or removal.¿ never insert the purewicktm female external catheter into vagina, anal canal, or other body cavities.¿ discontinue use if an allergic reaction occurs.¿ after use, this product may be a potential biohazard.Dispose of in accordance with applicable local, state and federal laws and regulations.Precautions: ¿ not recommended for patients who are: ¿ agitated, combative, or uncooperative and might remove the purewicktm female external catheter ¿ having frequent episodes of bowel incontinence without a fecal management system in place ¿ experiencing skin irritation or breakdown at the site ¿ experiencing moderate/heavy menstruation and cannot use a tampon ¿ do not use barrier cream on the perineum when using the purewicktm female external catheter.Barrier cream may impede suction.¿ proceed with caution in patients who have undergone recent surgery of the external urogenital tract.¿ always assess skin for compromise and perform perineal care prior to placement of a new purewicktm female external catheter.¿ maintain suction until the purewicktm female external catheter is fully removed from the patient to avoid urine backflow.Recommendations: ¿ perform each step with clean technique.In the home setting, wash hands thoroughly before device placement.¿ prior to connecting the purewicktm female external catheter to hospital wall suction tubing, verify suction function by covering the open end of the suction tubing with one hand and observing the pressure dial.If the pressure does not increase when the line is covered, verify that the tubing is secured, connected, and not kinked.¿ ensure the purewicktm female external catheter remains in the correct position after turning the patient.Remove the purewicktm female external catheter prior to ambulation.¿ properly placing the purewicktm female external catheter snugly between the labia and gluteus holds the purewicktm female external catheter in place for most patients.Mesh underwear may be useful for securing the purewicktm female external catheter for some patients.¿ assess device placement and patient¿s skin at least every 2 hours.¿ replace the purewicktm female external catheter every 8-12 hours or when soiled with feces or blood.¿ change suction tubing per hospital protocol or at least every thirty (30) days." h11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
 
Event Description
It was reported that patient was using the purewick female external catheter and started peeing out blood.Stated that his had happened two days ago and the patient had stated it happens when they use the purewick urine collection system.User stated that there was a blood clot in urine initially and then observed blood after that.It was noted that the patient had using this product for a week only and less than 90 days.Per follow up received via phone on 30jun2022, it was stated that the patient did seek medical treatment for the blood.The doctor determined that the patient had a urinary tract infection and prescribed medication.It was unknown what medication was provided for the urinary tract infection.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PUREWICK FEMALE EXTERNAL CATHETER
Type of Device
PUREWICK FEMALE EXTERNAL CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer (Section G)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer Contact
juan velez
8195 industrial blvd
covington 30014
7707846100
MDR Report Key15040522
MDR Text Key296050965
Report Number1018233-2022-05535
Device Sequence Number1
Product Code NZU
UDI-Device Identifier00801741189050
UDI-Public(01)00801741189050
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Consumer
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 10/11/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Lay User/Patient
Device Model NumberPWFX30
Device Catalogue NumberPWFX30
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 06/30/2022
Initial Date FDA Received07/18/2022
Supplement Dates Manufacturer Received10/11/2022
Supplement Dates FDA Received10/13/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient SexFemale
-
-