Catalog Number SGC0702
Device Problems Difficult to Insert (1316); Deformation Due to Compressive Stress (2889)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/13/2022
Event Type  malfunction  
Manufacturer Narrative
The device will not be returned for evaluation, the device was reportedly discarded.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
 
Event Description
This is being filed for compressive stress that caused damage to the soft tip.It was reported that on (b)(6) 2022, a patient presented with grade 4 mixed mitral regurgitation (mr) and a bilateral femoral bypass.The sgc was damaged during an attempt to access the puncture site.The access puncture was predilated with 16 f and 18 f dilators.When attempting to insert the sgc, it was impossible to advance.The sgc tip was visibly bending on the fluoroscopy as it was inserted into the femoral vein.The sgc was set aside to further dilate with a 20 f dilator.While inspecting the device, soft tip damage was noted.The surface was wrinkled and the curve was not smooth.A replacement completed the procedure successfully, and the mr was reduced to 2.There was no adverse patient effect or clinically significant delay.No additional information was provided regarding this issue.
 
Manufacturer Narrative
The device was not returned for analysis.A review of the lot history record revealed no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar complaints reported from this lot.Based on available information, the reported difficulty inserting the steerable guide catheter into anatomy appears to be due to procedural conditions.The reported sgc tip deformation appears to be a cascading event of the difficulty inserting the sgc into anatomy.There is no indication of product issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
G4 STEERABLE GUIDING CATHETER
Type of Device
CATHETER, STEERABLE
Manufacturer (Section D)
ABBOTT MEDICAL
5050 nathan lane n
plymouth MN 55442
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005070406
3885 bohannon drive
menlo park CA 94025
Manufacturer Contact
karen krouse
5050 nathan lane n
plymouth, MN 55442
6517565400
MDR Report Key15164376
MDR Text Key304920618
Report Number2135147-2022-00641
Device Sequence Number1
Product Code DRA
Combination Product (y/n)N
Reporter Country CodeSP
PMA/PMN Number
K190167
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 09/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/04/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/16/2023
Device Catalogue NumberSGC0702
Device Lot Number20316R314
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received09/09/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/17/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-