BOSTON SCIENTIFIC CORPORATION WOLVERINE CORONARY CUTTING BALLOON MONORAIL; CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING Back to Search Results
Model Number 3851
Device Problems Inflation Problem (1310); Material Rupture (1546)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 08/19/2022
Event Type  malfunction  
Event Description
It was reported that a balloon rupture occurred.The 80% stenosed target lesion was located in the non-tortuous and moderately calcified coronary artery.A 10mmx2.50mm wolverine coronary cutting balloon was selected for use.During the procedure, it was noted that the balloon was ruptured at 4 atm for a few seconds and could not inflate.The device was removed as normal and the procedure was completed with another of same device.No complications were reported and patient was stable post procedure.
 
Manufacturer Narrative
Device evaluated by mfr: the device was returned for evaluation.A visual examination identified that the balloon was returned with its wings intact.The returned device was attached to an encore inflation unit and positive pressure was applied in an attempt to inflate the balloon.Liquid was observed to be leaking from a balloon pinhole located in the proximal balloon cone.An examination of the balloon material and markerbands identified no issues which could potentially have contributed to this complaint.The rated burst pressure for this device is 12 atmospheres as per wolverine ifu.All blades were intact within their pads and fully bonded to the balloon material.A visual and tactile examination of the hypotube identified no issues.A visual and tactile examination of the shaft polymer extrusion identified no issues.The markerbands and tip and of the device were visually and microscopically examined, and no issues were noted with the device that may have potentially contributed to the complaint incident.
 
Event Description
It was reported that a balloon rupture occurred.The 80% stenosed target lesion was located in the non-tortuous and moderately calcified coronary artery.A 10mmx2.50mm wolverine coronary cutting balloon was selected for use.During the procedure, it was noted that the balloon was ruptured at 4 atm for few seconds and could not inflate.The device was removed as normal and the procedure was completed with another of same device.No complications were reported and patient was stable post procedure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
WOLVERINE CORONARY CUTTING BALLOON MONORAIL
Type of Device
CATHETER, PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA), CUTTING/SCORING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
4100 hamline ave n
arden hills, MN 55112
6515810888
MDR Report Key15451186
MDR Text Key303942358
Report Number2124215-2022-36627
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeCH
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative,Distributor
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 10/25/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/19/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/19/2024
Device Model Number3851
Device Catalogue Number3851
Device Lot Number0029255664
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/15/2022
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/13/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/20/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age60 YR
Patient SexMale
Patient Weight65 KG
-
-