Model Number CI-1400-01
Device Problems Mechanical Problem (1384); Battery Problem (2885); Output Problem (3005); Intermittent Communication Failure (4038)
Patient Problem Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 09/15/2022
Event Type  malfunction  
Event Description
The recipient reportedly experienced no sound and short battery life.Device testing revealed results within normal limits.External equipment was exchanged and programming adjustments were made and the issues improved slightly, however, the recipient proceeded with revision surgery.The recipient's device was explanted.The recipient was reimplanted with another cochlear device.
 
Manufacturer Narrative
Disclaimer: advanced bionics does not intend that this report be any admission of liability, fault or product defect.
 
Manufacturer Narrative
Advanced bionics considers the investigation into this reportable event as closed.The external visual inspection revealed silicone damage on the top cover of the device.This is believed to have occurred during revision surgery.The device passed the photographic imaging inspection.System lock could not be obtained at any spacing.An electrical test could not be performed due to no lock.The device passed some of the electrical tests performed.The device passed the mechanical test performed.This device had moisture that exceeded the residual gas analysis (rga) test limit.Based on an assessment of the rga data, it is determined that this device was non-hermetic.Corrective actions were implemented.This version of the hires 90k device is no longer distributed.This is the final report.Disclaimer: advanced bionics does not intend that this report be any admission of liability, fault or product defect.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HIRES 90K¿ IMPLANT
Type of Device
COCHLEAR IMPLANT
Manufacturer (Section D)
ADVANCED BIONICS, LLC
28515 westinghouse place
valencia CA 91355
Manufacturer Contact
heidi white
28515 westinghouse place
valencia, CA 91355
MDR Report Key15507046
MDR Text Key301249765
Report Number3006556115-2022-01550
Device Sequence Number1
Product Code MCM
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P960058
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 09/08/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date03/01/2006
Device Model NumberCI-1400-01
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/21/2022
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received Not provided
Initial Date FDA Received09/29/2022
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received11/17/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/22/2004
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age64 YR
Patient SexFemale
-
-