Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Erythema (1840); Unspecified Infection (1930); Necrosis (1971); Insufficient Information (4580)
|
Event Date 01/01/2017 |
Event Type
Injury
|
Manufacturer Narrative
|
(b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Does the surgeon believe that any of the ethicon products involved caused and/or contributed to the post-operative complications described in the article? which specific ethicon products have been used during the procedures (product code, lot number)? does the surgeon believe there was any deficiency with any of the ethicon products used in this procedure? if so, please provide details.Were the cases discussed in this article previously reported to ethicon? if yes, please provide a complaint reference number.Patient demographics? this report is related to a journal article; therefore, no product will be returned for analysis and the batch history records cannot be reviewed as the lot number has not been provided.(b)(4).The single complaint was reported with multiple events.There are no additional details regarding the additional events.Citation cite : doi: 10.3969/j.Issn.1000 - 0399.2017.08.021.
|
|
Event Description
|
Title: comparison of application effect of stapler and suture in skin suture of patients with calcaneal fracture.The aim of this study was to compare the effect of stapler suture and suture in skin suture of patients with calcaneal fracture.Sixty patients with calcaneal fracture admitted to the department of orthopaedics of the second people's hospital of anhui province from january 2013 to october 2016 were selected and treated with plate fixation and artificial bone.The patients were randomly divided into suture instrument group (n = 30) using skin stapler and suture group (n = 30) using common suture.Suture is manufactured by johnson & johnson.Reported complications included wound redness (n=3), induration (n=2), infection (n=2), skin necrosis (n=3).In conclusion the use of disposable skin stapler in the skin suture of patients with calcaneal fracture can shorten the operation time, with good drainage effect, good postoperative incision skin healing, shorten the hospital stay, and the overall effect is superior to the common suture.
|
|
Search Alerts/Recalls
|
|
|