Catalog Number 03666794001
Device Problem Image Display Error/Artifact (1304)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/14/2022
Event Type  malfunction  
Manufacturer Narrative
Occupation is patient/consumer.The meter was requested for investigation.Replacement product was sent.
 
Event Description
There was an allegation of a screen display issue on a coaguchek xs meter serial number (b)(4).On (b)(6) 2022, the patient turned on the meter and noticed there were some segments missing on the meter display.The patient checked the meter memory and saw there were segments missing in the 3 for the result of 2.3 inr from (b)(6) 2022.
 
Manufacturer Narrative
The meter was provided for investigation.The investigation found that the meter could not be turned on.The battery contacts and the circuit board were found to be contaminated by liquid which penetrated and corroded the solder contacts.The root cause is the event was found to be contamination of the contacts due to improper handling or maintenance.Per product labeling states, "wipe away residual moisture and fluids after cleaning the housing.Allow wiped areas to dry for at least 10 minutes before performing a test.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
COAGUCHEK ® XS SYSTEM
Type of Device
PROTHROMBIN TIME MONITOR
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
Manufacturer (Section G)
ROCHE DIAGNOSTICS GMBH
sandhoferstrasse 116
na
mannheim (baden-wurttemberg) 68305
GM   68305
Manufacturer Contact
amy nelson
9115 hague road
na
indianapolis, IN 46250
3174767531
MDR Report Key15754776
MDR Text Key307697420
Report Number1823260-2022-03551
Device Sequence Number1
Product Code GJS
UDI-Device Identifier04015630945689
UDI-Public04015630945689
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K062925
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Consumer
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 12/15/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/08/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Catalogue Number03666794001
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Date Manufacturer Received11/25/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-