Model Number 306546
Device Problem Physical Resistance/Sticking (4012)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/19/2022
Event Type  malfunction  
Event Description
It was reported while using bd posiflush¿ normal saline syringes, the plunger movement was difficult.There was no report of patient impact.Patient 2 of 3.The following information was provided by the initial reporter: detail: the 10ml saline syringe will not completely empty.It was reported they stop around the 1ml mark on the syringe and no amount of force will advance the syringe.The current sample was pushed so hard than you can no longer withdraw the syringe back.This has happened 3 times this morning.One patient didn't get the entire medication, and another got an iv replaced that did not need to occur.
 
Manufacturer Narrative
Investigation summary it was reported the syringe will not completely empty, and no amount of force will advance it.To aid the investigation, one empty sample with no packaging flow wrap, or tip cap, was received for evaluation by our quality team.A visual inspection was performed and no defects or imperfections were observed.The sample was then tested for sustaining force, which is the force applied to the plunger rod while moving downwards when expelling the saline solution, and the result was within specification.A device history record review was completed for provided material number 306546, lot number 2179528.The review did not reveal any detected quality issues during the production of this lot that could have contributed to the reported defect.To date, there have been no other similar events reported for this lot.Based on the investigation and with the returned sample analysis the symptom reported by the customer could not be confirmed, and a probable root cause could not be offered.Complaints received for this device and reported condition will continue to be tracked and trended.Our quality team regularly reviews the collected data for identification of emerging trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD POSIFLUSH¿ NORMAL SALINE SYRINGES,
Type of Device
SALINE, VASCULAR ACCESS FLUSH
Manufacturer (Section D)
BD MEDICAL (BD WEST) MEDICAL SURGICAL
1852 10th avenue
columbus NE 68601
Manufacturer (Section G)
BD MEDICAL (BD WEST) MEDICAL SURGICAL
1852 10th avenue
columbus NE 68601
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15810067
MDR Text Key303989221
Report Number1911916-2022-00649
Device Sequence Number1
Product Code NGT
UDI-Device Identifier30382903065463
UDI-Public(01)30382903065463
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K003553
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 11/10/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/16/2022
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number306546
Device Catalogue Number306546
Device Lot Number2179528
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/01/2022
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/25/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/28/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial