Catalog Number 1070300-23
Device Problem Contamination /Decontamination Problem (2895)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/19/2022
Event Type  malfunction  
Manufacturer Narrative
A visual inspection was performed on the returned device.Additionally, the device was sent to the chemical lab (chem) for further analysis.The chem report determined that the unknown fiber resembled polypropylene by comparing spectrums of fourier-transform infrared spectroscopy (ftir).The reported contamination/decontamination problem was confirmed.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Additionally, a review of the complaint history identified no similar incidents from this lot.The investigation was unable to determine a conclusive cause for the reported contamination/decontamination problem.There is no indication of a product quality issue with respect to manufacture, design, or labeling.
 
Event Description
It was reported that when opening the package of the 3.0x23 mm xience xpedition stent delivery system (sds), it was noted that there was a thin steel wire on the strut of the stent.The device was not used and there was no patient involvement.A new same size sds was used to complete the procedure.There was no clinically significant delay in the procedure.Returned device analysis identified there was blood on and in the device and there was a fiber like material noted on the proximal portion of the stent.The account stated the device was not inserted.No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE XPEDITION EVEROLIMUS ELUTING CORONARY STENT SYSTEM
Type of Device
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005718570 (P099)
cashel road
clonmel tipperary
EI  
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key16266950
MDR Text Key308444561
Report Number2024168-2023-00953
Device Sequence Number1
Product Code NIQ
Combination Product (y/n)Y
Reporter Country CodeCH
PMA/PMN Number
P110019
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative,Distributor
Reporter Occupation Physician
Type of Report Initial
Report Date 01/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/30/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number1070300-23
Device Lot Number1122041
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/22/2022
Is the Reporter a Health Professional? Yes
Date Manufacturer Received01/05/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/05/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-