Catalog Number BXA062902E
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Obstruction/Occlusion (2422)
Event Date 02/01/2021
Event Type  Injury  
Event Description
Reportedly on (b)(6) 2020, this patient underwent an endovascular repair of a thoracoabdominal aneurysm, which was treated with a fenestrated and branched stent graft component (zenith® t-branch® thoracoabdominal endovascular graft, cook medical).During the procedure planning, it was determined that the superior mesenteric artery, right and left renal artery will be incorporated in the fenestrated and branched endograft.Three gore® viabahn® vbx balloon expandable endoprostheses (viabahn® vbx device) were implanted in the superior mesenteric artery, right and left renal artery.Reportedly, the whole procedure was uneventful, aortic access was successfully gained, device deployed as intended, catheters were successfully removed and the patency of the devices were confirmed at the end of the procedure.The patient received an additional antiplatelet medication during the procedure.According to reports, on (b)(6) 2021 during a follow-up visit, a cta was performed and an adverse event termed " right renal stent occlusion" was discovered.The relationship was recorded as device related.
 
Manufacturer Narrative
Heparin surface incorporates carmeda heparin manufactured from heparin sodium api, which is covalently bound to the device surface and is essentially non-eluting.Device evaluated by mfr code b20: the device remains implanted in the patient.Therefore a device evaluation could not be performed.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Manufacturer Narrative
H6: corrected imdrf codes.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® VIABAHN® VBX BALLOON EXPANDABLE ENDOPROSTHESIS
Type of Device
ILIAC COVERED STENT, ARTERIAL
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL ECHO RIDGE B/P
3250 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
wilson okeke
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key16395316
MDR Text Key309887534
Report Number2017233-2023-03728
Device Sequence Number1
Product Code PRL
Combination Product (y/n)Y
Reporter Country CodeSP
PMA/PMN Number
P160021
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Study
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 07/24/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/17/2023
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date08/16/2021
Device Catalogue NumberBXA062902E
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received07/21/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured08/17/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age82 YR
Patient SexMale
-
-