MAUDE Adverse Event Report: BAXTER HEALTHCARE CORPORATION EM 2400, MAIN MODULE; SYSTEM/DEVICE, PHARMACY COMPOUNDING

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BAXTER HEALTHCARE CORPORATION EM 2400, MAIN MODULE; SYSTEM/DEVICE, PHARMACY COMPOUNDING Back to Search Results
Catalog Number 2400M
Device Problem Break (1069)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/22/2023
Event Type  malfunction  
Event Description
It was reported unspecified damage was observed to the rotor door on an em 2400, main module.There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
The device has been received and the evaluation is in progress.Should additional relevant information become available, a supplemental report will be submitted.
 
Manufacturer Narrative
Correction d4: expiration date (remove ni and replace with na).The device was received for evaluation with unknown fluids on the unit.A visual inspection was performed which observed light scratches on the top plate in slightly used condition, main module cover contaminated and magnets are reversed on pump cover.A functional electrical safety test was performed and the device passed.Functional system tests were performed and the device failed the large & small volume occlusion, syringe occlusion system testing with multiple occlusion errors.The reported condition of damaged rotor door (pump cover) was verified.The cause of the condition could not be determined, however, reversed magnets on pump cover will cause reverse polarity and produce the occlusion failures.Magnets may have became dislodged from normal everyday use and re-installed incorrectly by customer in reverse polarity.The door with magnets will be replaced to resolve the issue.A service history review revealed no indication that the parts replaced during servicing caused or contributed to the reported event.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EM 2400, MAIN MODULE
Type of Device
SYSTEM/DEVICE, PHARMACY COMPOUNDING
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
PLEXUS CORPORATION
2500 millbrook drive
buffalo grove IL 60089
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key16400814
MDR Text Key310078886
Report Number1416980-2023-00536
Device Sequence Number1
Product Code NEP
UDI-Device Identifier00085412482637
UDI-Public(01)00085412482637
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 03/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/17/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number2400M
Device Lot NumberN/A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/01/2023
Is the Reporter a Health Professional? No
Date Manufacturer Received02/21/2023
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-