Catalog Number AB9G14100090 |
Device Problem
Activation, Positioning or Separation Problem (2906)
|
Patient Problem
Insufficient Information (4580)
|
Event Date 02/20/2023 |
Event Type
Injury
|
Manufacturer Narrative
|
Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Event Description
|
It is reported there were issues deploying an abre stent.Another stent had to be added to expand from the inside.No damage noted to packaging.No issues noted when removing the device from the hoop/tray.
|
|
Manufacturer Narrative
|
Image analysis the customer returned five images for evaluation image 1 depicts the shelf carton of the abre device, the lot number on the box correlates with the lot number in the customer complaint.Image 2 appears to depict 3 identifiable stents within the patients vasculature system within the pelvic region.The radiopaque markers are visible on the stents.Image 3 depicts the shelf carton of the abre device, the lot number on the box correlates with the lot number in the customer complaint.Image 4 appears to depict 3 identifiable stents within the patients vasculature system within the pelvic region.The radiopaque markers are visible on the stents.Image 5 appears to depict 3 identifiable stents within the patients vasculature system within the pelvic region.The image appears to depict overlapping on two of the stents by the position of the radiopaque markers.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
|
|
Search Alerts/Recalls
|
|
|