Model Number 24653
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Vascular Dissection (3160)
Event Date 09/05/2019
Event Type  Injury  
Event Description
It was reported that a dissection occurred.The subject underwent treatment with a study device on september 05, 2019 as part of the eminent clinical trial.The target lesion was located in left distal superficial femoral artery (sfa) with 100% stenosis and was 80 mm long with a proximal reference vessel diameter of 4.7 mm and distal reference vessel diameter of 5.3 mm and was classified as tasc ii b lesion.The target lesion was treated with pre-dilatation followed by placement of a 7 mm x 100 mm study stent.Post treatment, dissection was noted, hence an additional study stent 6 mm x 80 mm was placed.Following post dilation, residual stenosis was 0%.On (b)(6) 2019, the subject was discharged with antiplatelet therapy.
 
Manufacturer Narrative
Reporter address 1: (b)(6).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELUVIA DRUG-ELUTING VASCULAR STENT SYSTEM
Type of Device
STENT, SUPERFICIAL FEMORAL ARTERY, DRUG-ELUTING
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
ballybrit business park
galway
EI  
Manufacturer Contact
jeff wallner
4100 hamline ave n
arden hills, MN 55112
6515811560
MDR Report Key16651198
MDR Text Key312399112
Report Number2124215-2023-14754
Device Sequence Number1
Product Code NIU
Combination Product (y/n)Y
Reporter Country CodeAU
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Study,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial
Report Date 03/30/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date02/21/2021
Device Model Number24653
Device Catalogue Number24653
Device Lot Number0023510328
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/17/2023
Initial Date FDA Received03/30/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/22/2019
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age66 YR
Patient SexMale
Patient RaceWhite
-
-