Model Number G158
Device Problems Premature Discharge of Battery (1057); Battery Problem (2885)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/24/2023
Event Type  malfunction  
Event Description
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) has depleted from 7.5 years to 3.5 years battery remaining.Moreover, this patient has undergone a daily radiation therapy until six weeks from now.Boston scientific technical services (ts) explained that this was due to the daily telemetry and the nightly full uploads on latitude.Data analysis was requested and showed that this device was behaving in a manner consistent with frequent programmer interrogations.The power will return to normal once these interrogations conclude.The longevity impact is variable and dependent on the number and total length of the sessions.The impact will be minimized by keeping the sessions short.Furthermore, the baseline power was approximately 50 micro watts.The present average power is above 100 micro watts and is climbing.Two months of operation at twice the average power may reduce the overall longevity by 2 months when the normal power is restored.Additional information received which indicated that the average power increases slowly and may continue to rise as these interrogations continue.There is no risk of the device reaching elective replacement indicator (eri).As of this time, this device remains in service.No adverse patient effects were reported.
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DYNAGEN X4 CRT-D
Type of Device
DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER, WITH CRT-D
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key16692122
MDR Text Key312818326
Report Number2124215-2023-16262
Device Sequence Number1
Product Code NIK
UDI-Device Identifier00802526534904
UDI-Public00802526534904
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P010012/S341
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 04/06/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/06/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date08/24/2022
Device Model NumberG158
Device Catalogue NumberG158
Device Lot Number244122
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received03/24/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/03/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age56 YR
Patient SexMale
-
-