• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: KARL STORZ SE & CO. KG ELECTRODE, BIPOLAR; ENDOSCOPIC ELECTROSURGICAL ELECTRODE, BIPOLAR, SINGLE-USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

KARL STORZ SE & CO. KG ELECTRODE, BIPOLAR; ENDOSCOPIC ELECTROSURGICAL ELECTRODE, BIPOLAR, SINGLE-USE Back to Search Results
Model Number 011050-10
Device Problem Material Fragmentation (1261)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/30/2023
Event Type  Injury  
Manufacturer Narrative
The affected device has been requested for investigation by the manufacturer.Device was not yet returned for investigation.The event is filed under internal karl storz complaint id: (b)(4).
 
Event Description
The event occurred in france.It was reported that when inserting the resector into the uterus, they tried to resect, and the metal tip of the disposable loop broke in the uterus, leaving a piece of a few millimeters that had to be removed.
 
Manufacturer Narrative
Based on the multiple bends and the rupture of the welding joint on the neutral electrode it is most likely, that the neutral loop became trapped in the inner sheath and tore apart.The amount of damage done to the neutral electrode indicates that the welding joint was in place but was overloaded during the event.Thus, the root cause is a user error.The event is filed under internal karl storz complaint id: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELECTRODE, BIPOLAR
Type of Device
ENDOSCOPIC ELECTROSURGICAL ELECTRODE, BIPOLAR, SINGLE-USE
Manufacturer (Section D)
KARL STORZ SE & CO. KG
dr.-karl storz-strasse 34
tuttlingen, 78532
GM  78532
Manufacturer (Section G)
KARL STORZ SE & CO. KG
dr.-karl storz-strasse 34
tuttlingen, 78532
GM   78532
Manufacturer Contact
anja fair
2151 e grand ave.
el segundo, CA 90024
MDR Report Key16744697
MDR Text Key313347995
Report Number9610617-2023-00078
Device Sequence Number1
Product Code HIH
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
K882270
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 05/15/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number011050-10
Device Catalogue Number011050-10
Device Lot Number841338
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/30/2023
Initial Date FDA Received04/14/2023
Supplement Dates Manufacturer Received05/12/2023
Supplement Dates FDA Received05/15/2023
Was Device Evaluated by Manufacturer? Yes
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-