Model Number HL-390
Device Problems Device Alarm System (1012); No Audible Alarm (1019)
Patient Problems Insufficient Information (4580); No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Date of event and udi number is unknown, no information has been provided to date.Investigation including root cause analysis is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.
 
Event Description
It was reported that the unit was not respond to the "alarm test" button.The customer suspected led's (light-emitting diodes) were disconnected, and the speaker was malfunctioning.The customer attempted to induce the "low water" alarm and the "tubing disconnected" alarm and the leds (light-emitting diodes) did not respond nor was there audible alarm sounds.There has been no report of patient involvement or no observable clinical symptoms or a change in symptoms identified in the patient.
 
Event Description
Additional information received via email.The problem was discovered during regularly scheduled maintenance.No patient involvement was reported.
 
Manufacturer Narrative
G2 email is: (b)(4).One device was received.Per visual inspection, light emitting diode (led) lights on printed circuit board (pcb) were damaged.Per functional testing, when the alarms were triggered, the speaker made no sound.The complaint was confirmed.The root cause was a faulty speaker and broken leds on pcb.It was unknown what caused the condition.The product's history records were reviewed and there were no non-conformances nor service-related issues that would have resulted in the reported complaint.Replaced pcb, o-rings, and reservoir gasket.Calibrated the device.The device passed all functional and delivery tests.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LEVEL 1 HOTLINE FLUID WARMER, 390
Type of Device
WARMER, THERMAL, INFUSION FLUID
Manufacturer (Section D)
OAKDALE
3350 granada ave n
oakdale MN 55128
Manufacturer (Section G)
NULL
Manufacturer Contact
jim vegel
MDR Report Key16753042
MDR Text Key313438023
Report Number3012307300-2023-04204
Device Sequence Number1
Product Code LGZ
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K911383
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 02/27/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/17/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberHL-390
Device Catalogue NumberCON-HL-390
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received11/30/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/08/2017
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-