MAUDE Adverse Event Report: THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE WITH EM-TEC ADULT FLOW PROBE (VAS/ECMO); CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

THORATEC SWITZERLAND GMBH CENTRIMAG 2ND GENERATION PRIMARY CONSOLE WITH EM-TEC ADULT FLOW PROBE (VAS/ECMO); CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS Back to Search Results
Model Number 201-90401
Device Problems Infusion or Flow Problem (2964); Insufficient Information (3190)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 04/14/2023
Event Type  malfunction  
Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer's investigation is complete.
 
Event Description
It was reported that the centrimag pump flow was not increasing as the speed was increased.After the centrimag console and centrimag motor were exchanged, the pump was operating correctly.Related centrimag motor mfr #: 3003306248-2023-01923.
 
Event Description
Additional information: there were no alarms during this event.
 
Manufacturer Narrative
Manufacturer's investigation conclusion: the reported event of the flow not increasing when speed was increased was not confirmed.The centrimag 2nd generation primary console (serial #: (b)(6)) was returned for analysis and a log file was downloaded for review.A review of the downloaded log file showed events spanning approximately 4 days (11mar2023 ¿ 12mar2023, 14mar2023 ¿ 15mar2023 per time stamp).Throughout the log file, the motor speed was increased and decreased several times and the flow subsequently changed with no issue.There were no issues related to the reported event noted within the log file.Upon functional testing, the console was connected to the returned and associated centrimag motor (serial #: (b)(6)), and calibrated mock loop, mag monitor, and flow probe.The console operated the motor at a speed of 5000 rpm with a flow of ~9 lpm for an extended operation.The speed was then lowered to 1000 rpm and the flow subsequently dropped to ~1.5 lpm and operated as intended for extended operation.There were no issues noted during testing.The reported event was unable to be reproduced during this investigation.The root cause for the reported event was unable to be conclusively determined through this analysis.The device history records were reviewed for the centrimag 2nd generation primary console (serial #: (b)(6)) and the console was found to pass all manufacturing and quality assurance (qa) specifications.The 2nd generation centrimag system operating manual (rev.L) section 4 entitled "warnings & precautions" warns "one additional 2nd generation centrimag primary console, motor and flow probe are required as backup system in the immediate vicinity of each patient whenever the centrimag or pedivas blood pump is used.The backup console must be connected to the backup motor and to the backup flow probe, have a battery charge sufficient for at least one hour of operation, be connected to ac power (except during transport) and be immediately available should the main console, motor or flow probe experience a malfunction." the 2nd generation centrimag system operating manual (rev.L) section 10 entitled "emergency and troubleshooting" states that "the recommended practice whenever there is a 2nd generation centrimag primary console or motor malfunction is to replace the console and motor as a set.Remove the blood pump from the malfunctioning motor and console and place the blood pump in the backup motor and console to continue patient support.Do not exchange individual motors or individual consoles during patient support." the 2nd generation centrimag system operating manual (rev.L) table 13 entitled ¿console alarms and alerts¿ addresses how to properly interpret and troubleshoot all system alarms including f3 alarms.No further information was provided.The manufacturer is closing the file on this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTRIMAG 2ND GENERATION PRIMARY CONSOLE WITH EM-TEC ADULT FLOW PROBE (VAS/ECMO)
Type of Device
CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ  CH-8005
Manufacturer (Section G)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ   CH-8005
Manufacturer Contact
bob fryc
6035 stoneridge drive
pleasanton, CA 94588
7818528204
MDR Report Key16777390
MDR Text Key313660139
Report Number3003306248-2023-01922
Device Sequence Number1
Product Code DWA
Combination Product (y/n)N
Reporter Country CodeSP
PMA/PMN Number
K020271
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 07/27/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number201-90401
Device Lot Number6214091
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 04/18/2023
Initial Date FDA Received04/20/2023
Supplement Dates Manufacturer Received07/18/2023
Supplement Dates FDA Received07/27/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/14/2017
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-