Model Number 50-601XL
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Foreign Body In Patient (2687)
Event Date 03/31/2023
Event Type  malfunction  
Manufacturer Narrative
Hologic is submitting this report in accordance with 21.Cfr part 803.The submission is based upon the currently available information.The submission of this report does not represent a confirmation of device malfunction involving the hologic products in the event described.A device history record (dhr) review was conducted for the reported lot/serial number.The device was released meeting all qa specifications.We are currently unable to establish a relationship between the device and the issue reported.H3: the device involved in this event was not returned for evaluation purposes therefore visual and functional analysis of the product could not be performed.We are unable to confirm a relationship between the device and the issue reported and a definitive root cause for the reported event could not be determined.The information obtained during complaint investigation will be included in our global complaint trending and product surveillance will continue to monitor complaints of this type for adverse trends.If the product is received or additional information is obtained, the investigation will be reopened accordingly per standard operating procedure.
 
Event Description
It was reported that on (b)(6) 2023 a myosure procedure was performed, and there appeared to be glittery pieces floating in the cavity, the doctor chose to continue cutting with the same device, and less of the glittery pieces were saw as the procedure continued.Procedure was completed successfully with the same device.Repeat hysteroscopy and a novasure procedure were performed after the myosure procedure, and the doctor reported that the cavity appeared clear and did not see any evidence of metal shavings in the cavity.No patient injury reported.No additional information is available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MYOSURE XL
Type of Device
HYSTEROSCOPE (AND ACCESSORIES)
Manufacturer (Section D)
HOLOGIC, INC
250 campus drive
marlborough MA 01752
Manufacturer (Section G)
HOLOGIC, INC.
250 campus drive
marlborough MA 01752
Manufacturer Contact
ariel lafuente
562 parkway
coyol free zone building b24
san jose 20102
MDR Report Key16831926
MDR Text Key314179277
Report Number1222780-2023-00142
Device Sequence Number1
Product Code HIH
UDI-Device Identifier15420045507654
UDI-Public(01)15420045507654(17)250927(10)22K13RH
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K181974
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date 05/17/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Model Number50-601XL
Device Catalogue Number50-601XL
Device Lot Number22K13RH
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 03/31/2023
Initial Date FDA Received04/28/2023
Supplement Dates Manufacturer Received03/31/2023
Supplement Dates FDA Received05/17/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured11/13/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient SexFemale
-
-