Model Number 201-90401
Device Problem Insufficient Information (3190)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/28/2023
Event Type  malfunction  
Event Description
It was reported that log files revealed a few s3 system fault alarms on 28jan2023 at 17:52 and on 31jan2023 at 9:20 and 9:21 that occurred after the console was powered on.These alarms correlated to a ¿can bus send error¿ sub-fault, and the console was not observed to have been in patient use during these times.The console was observed to have been shut down shortly after each alarm, resolving the alarms.
 
Manufacturer Narrative
No further information was provided.A supplemental report will be submitted once the manufacturer¿s investigation is completed.
 
Manufacturer Narrative
Manufacturer's investigation conclusion: the reported event of s3: system fault alarms was confirmed via the log file.A log file was extracted from the centrimag console when it was returned and evaluated under a separate event for a separate reason.A few s3: system fault alarms were observed on (b)(6) 2023 and on (b)(6) 2023, occurring shortly after the console was powered on.These alarms correlated to a sub-fault that was indicative of a communication error, and the console was not observed to have been in patient use during these times.The console was observed to have been shut down shortly after each alarm.The centrimag console (serial number (b)(6)) was not returned for analysis for this event.The root cause of the reported event was unable to be conclusively determined through this analysis.Review of the device history record for centrimag console, serial number (b)(6), showed the device was manufactured in accordance with manufacturing and qa specifications.The 2nd generation centrimag system operating manual section 3 "warnings and precautions" warns "one additional 2nd generation centrimag primary console, motor and flow probe are required as backup system in the immediate vicinity of each patient whenever the centrimag or pedivas blood pump is used.The backup console must be connected to the backup motor and to the backup flow probe, have a battery charge sufficient for at least one hour of operation, be connected to ac power (except during transport) and be immediately available should the main console, motor or flow probe experience a malfunction." the 2nd generation centrimag system operating manual section 11.1-"appendix i ¿ console alarms and alerts" contains a list of console alarms and alerts, including s3 alarms, as well as appropriate operator response to these events.No further information was provided.The manufacturer is closing the file on this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CENTRIMAG 2ND GENERATION PRIMARY CONSOLE WITH EM-TEC ADULT FLOW PROBE (VAS/ECMO)
Type of Device
CONTROL, PUMP SPEED, CARDIOPULMONARY BYPASS
Manufacturer (Section D)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ  CH-8005
Manufacturer (Section G)
THORATEC SWITZERLAND GMBH
technoparkstrasse 1
zurich CH-80 05
SZ   CH-8005
Manufacturer Contact
bob fryc
6035 stoneridge drive
pleasanton, CA 94588
7818528204
MDR Report Key17172235
MDR Text Key317653932
Report Number3003306248-2023-01952
Device Sequence Number1
Product Code DWA
Combination Product (y/n)N
Reporter Country CodeSP
PMA/PMN Number
K020271
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 07/12/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/21/2023
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number201-90401
Device Lot Number7075559
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received06/23/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured06/17/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-