OLYMPUS WINTER & IBE GMBH RESECTION SHEATH, 24 FR. Back to Search Results
Model Number A22041A
Device Problems Break (1069); Mechanical Problem (1384)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/06/2023
Event Type  malfunction  
Event Description
The customer reported to olympus that the tip on the sheath was loose.No delay was reported.There were no reports of patient harm.
 
Manufacturer Narrative
The subject device was returned to an olympus repair center for evaluation and the customer¿s reported issue was confirmed.The device evaluation, it was found that the ceramic tip fell off.In addition it was found that the black cap was missing, and the sealing ring was damaged.Manufacturing and quality control review was performed for the affected lot or serial number without showing any non-conformities or deviations regarding the described issue.The investigation is ongoing and follow up with the user facility is currently being performed.A supplemental report will be submitted upon completion of the investigation or if any additional information is provided.
 
Manufacturer Narrative
His report is being supplemented to provide additional information based on the legal manufacturer's final investigation.Based on the results of the investigation, the root cause could not be determined.It is likely the damage to the tip was caused by one of the following; a thermal/mechanically induced impact, wear and tear, improper handling, and/or a mechanical overload (such as impact from a fall, shock, or similar stress).It was further noted that it cannot be determined with certainty, whether there was pre-existing damage or if it had occurred during the last procedure or last reprocessing.The instructions for use (ifu) provides a warning that the ceramic tip can break due to mechanical loading or thermally induced straining: ¿4 before use warning infection control risk properly reprocess the product before first and each subsequent use following the instructions in this manual and in the system guide endoscopy.Improper and/or incomplete reprocessing can cause infection of the patient and/or medical personnel.4.1 inspection and testing inspecting the product visually inspect the product.Make sure that it has: -- no corrosion -- no dents -- no scratches ceramic insulation at distal end visually inspect the ceramic insulation at the sheath¿s distal end before each use.Do not use the instrument in case of damage (e.G.Cracks, fractures).Warning risk of injury impact, fall, shock or similar stress can damage the ceramic insulation at the sheath¿s distal end.Damaged instruments can cause injuries to the patient and/or user.Do not use the instrument if damaged.Damaged product if the product is damaged or does not function properly, contact an olympus representative or an authorized service center.¿ olympus will continue to monitor field performance for this device.
 
Manufacturer Narrative
This report is being supplemented to provide additional information obtained from the customer.
 
Event Description
Additional information received by customer: the unspecified therapeutic procedure was completed with a similar device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RESECTION SHEATH, 24 FR.
Type of Device
RESECTION SHEATH
Manufacturer (Section D)
OLYMPUS WINTER & IBE GMBH
kuehnstrasse 61
hamburg, hamburg 22045
GM  22045
Manufacturer (Section G)
OLYMPUS WINTER & IBE GMBH
kuehnstrasse 61
hamburg
Manufacturer Contact
todd brill
800 west park drive
westborough, MA 01581
5082077661
MDR Report Key17260974
MDR Text Key318651158
Report Number9610773-2023-01800
Device Sequence Number1
Product Code HIH
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K931994
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup,Followup
Report Date 09/14/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberA22041A
Device Catalogue NumberA22041A
Device Lot Number17ZW-0109
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/08/2023
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 06/06/2023
Initial Date FDA Received07/05/2023
Supplement Dates Manufacturer Received07/11/2023
09/11/2023
Supplement Dates FDA Received08/08/2023
09/14/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/01/2017
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-