Catalog Number PW200 |
Device Problem
Increase in Suction (1604)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 07/06/2023 |
Event Type
malfunction
|
Event Description
|
It was reported that the purewick urine collection system had too much suction.When turned on, the suction collapses the lid.Customer stated that they changed the kit and wick twice and when they removed the middle of lid and shorter tubing, the canister expands with a loud whoosh sound.The machine did not suction any urine during use.
|
|
Manufacturer Narrative
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.H11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
|
|
Event Description
|
It was reported that the purewick urine collection system had too much suction.When turned on, the suction collapses the lid.Customer stated that they changed the kit and wick twice and when they removed the middle of lid and shorter tubing, the canister expands with a loud whoosh sound.The machine did not suction any urine during use.
|
|
Manufacturer Narrative
|
The reported event was inconclusive because no sample was returned.It is unknown whether the device had met relevant specifications.The product was used for treatment purposes.It was unknown whether the product had caused the reported failure.A potential root cause for this failure could be "inadequate component (pump and relief valve) selection".The serial number is unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: ¿place the collection canister (c) in the purewick¿ urine collection system base and press down firmly on the lid making sure the lid is sealed.Attach the pump tubing (d) to the purewick¿ urine collection system connector port (f) and the connector port (e) on the collection canister lid.Attach the collector tubing (g) to the connector port (h) on the collection canister lid.Connect the other end of the collector tubing securely to a purewick¿ external catheter (i).[note the letters correlate to a diagram within the ifu].Caution: it is important that the port connections be connected correctly and securely for proper operation of the purewick¿ urine collection system." operating suction range: approximately 120 mmhg ¿ 140 mmhg (2.3 ¿ 2.7 psi) maximum suction level: 182 mmhg (3.5 psi)." h11: section a through f - the information provided by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : the device was not returned.
|
|