• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 7" (18 CM) APPX 0.24 ML, SMALLBORE EXT SET W/CLAVE¿, CLAMP, ROTATING LUER; STOPCOCK, I.V. SET

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V. 7" (18 CM) APPX 0.24 ML, SMALLBORE EXT SET W/CLAVE¿, CLAMP, ROTATING LUER; STOPCOCK, I.V. SET Back to Search Results
Catalog Number MS933
Device Problems Fluid/Blood Leak (1250); Connection Problem (2900)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 06/22/2023
Event Type  malfunction  
Manufacturer Narrative
The actual sample was not returned for evaluation, however, two photo samples were provided.One photo shows a patient's arm connected to an icu medical device and there is blood observed around the arm and the blanket, however it's not clear where the blood came from.In the second photo the same item is observed, but now disconnected.It is not clear how the product was connected.No additional damage or abnormally were observed.Complaint of product did not connect properly to line cannot be confirmed, due to no product sample being returned for evaluation and a probable cause cannot be determined.The device history review (dhr) for lot 13641832 was reviewed and no non conformities were found that would have led to the reported complaint.Additional reporter: (b)(6).
 
Event Description
The event involved a 7" (18 cm) appx 0.24 ml, smallbore ext set w/clave¿, clamp, rotating luer where it was reported that the product did not connect properly to line and leaked patient's blood.The status of the product was during set up and infusion.The set up was, connected to intravenous (iv) catheter cannula, then the extension tubing was connected to iv bag tubing and iv bag.The medications involved were iv saline + vitamin and minerals (vit.C, magnesium, calcium gluconate, b12 etc).It was also reported that the blood loss was not clinically significant and no medical intervention was required, other than replacing the extension tubing.The tubing was replaced twice, and three times had got two faulty ones in a row, needing to open 3 sets on one patient.There was patient involvement, however no report of patient harm.This captures 14 out of 19 occurrences.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
7" (18 CM) APPX 0.24 ML, SMALLBORE EXT SET W/CLAVE¿, CLAMP, ROTATING LUER
Type of Device
STOPCOCK, I.V. SET
Manufacturer (Section D)
ICU MEDICAL DE MEXICO, S. DE R.L. DE C.V.
avenida cuarzo no. 250
ensenada, b.cfa. 22790
MX  22790
Manufacturer Contact
michael visocnik
600 n. field dr.
lake forest, IL 60045
2247062300
MDR Report Key17508667
MDR Text Key321050011
Report Number9617594-2023-00527
Device Sequence Number1
Product Code FMG
UDI-Public(01)(17)280501(10)13641832
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K964435
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 07/17/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberMS933
Device Lot Number13641832
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 07/17/2023
Initial Date FDA Received08/11/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/01/2023
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
INTRAVENOUS CATHETER CANNULA, UNK MFR; UNSPECIFIED INTRAVENOUS TUBING, UNK MFR; UNSPECIFIED IV SALINE,VITAMIN,MINERALS BAG,UNK MFR
-
-